Operating and Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr. 10 546 230...
IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user.
Page 5
Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions. Contact Miele’s Technical Service Department for examination, repair or adjustment.
Page 6
Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operation faults. Defective components should be replaced by Miele original parts only. Only with these parts can the manufacturer guarantee the safety of the appliance.
Page 7
IMPORTANT SAFETY INSTRUCTIONS If the power cord is damaged, it must only be replaced by a qualified service technician. During installation, maintenance, and repair work, the ventilation hood must be disconnected from the electrical supply. It is only completely isolated from the electricity supply if one of the following applies: –...
Page 8
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING*: – a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS.
Page 9
IMPORTANT SAFETY INSTRUCTIONS Overheated oils and fats can ignite and set the ventilation hood on fire. When cooking with oils or fats, do not leave pots, pans or fryers unattended. Never leave an electric grill unattended when grilling. Fat and debris deposits impair the proper functioning of the ventilation hood.
Page 10
IMPORTANT SAFETY INSTRUCTIONS Proper installation WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: – a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Page 11
Never use a steam cleaner to clean the ventilation hood. The steam can reach the electrical components and cause a short circuit. Accessories Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty will become void.
Page 12
IMPORTANT SAFETY INSTRUCTIONS FCC Declaration of Conformity These devices comply with FCC Rules Part 15. This equipment has been tested and found to be in compliance with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules of Operation and is subject to the following conditions: These devices may not cause harmful interference.
Caring for the environment Disposal of the packing Disposal of your old appliance material Do not dispose of this appliance with your household waste. The cardboard box and packing materials protect the appliance during Old appliances may contain materials shipping. They have been designed to that can be recycled.
Description of functions The following functions are available on Recirculation mode your ventilation hood, depending on the (Recirculation mode ventilation hoods model: require charcoal filters. These are available as optional accessories: see Vented mode "Technical Data") Air entering through the intake is Air entering through the intake is first cleaned by the grease filters and cleaned by the grease filters and then...
Page 17
Guide to the appliance a Fold-down canopy b DADC 6000 canopy Available as an optional accessory for concealing ducting to the ceiling. c Charcoal filter Optional accessory for recirculation mode d Overhead cooktop lighting e Control panel The symbols act as sensor buttons. You select the functions by pressing these buttons.
Operation (Automatic mode) When Con@ctivity 2.0 is active, the Reaction time hood always operates in Automatic Changing the power setting on the mode (see "Activating Con@ctivity cooktop does not lead to an immediate 2.0"). increase or decrease in cooking vapors. See "Cooking without Con@ctivity 2.0"...
Page 19
Operation (Automatic mode) Cooking process Deactivation If, for example, you switch on a Turn off all burners. burner at the highest power setting to Over the next few minutes, the heat cookware in preparation for ventilation hood fan setting will searing and then reduce the power decrease one level at a time until the level after approx.
Operation (Automatic mode) Temporarily exiting Automatic Resuming Automatic mode mode The ventilation hood resumes Automatic mode: To temporarily exit the Automatic mode when cooking: If the ventilation hood has not been used for a period of approx. 5 Manually select a different fan level, minutes after the manual selection of a fan level, or ...
Operation (Manual mode) Cooking without Con@ctivity Selecting the delayed shut 2.0 (Manual mode) down time The hood can be operated manually if: It is a good idea to let the fan run for a few more minutes after cooking in order –...
Operation (Manual mode) Turning power management on/off Power management Turn off the blower and the lighting. The ventilation hood features a power management system to help save Press the delayed shut down button energy. The fan power level is reduced ...
Operation (Automatic and Manual modes) The indicators 1 to IS show the current Filter saturation indicator time setting: The number of hours the hood has Indicator 1 ......20 hours been in operation is stored in appliance memory. Indicator 2 ....... 30 hours The filter saturation indicators show Indicator 3 .......
Operation (Automatic and Manual modes) Activating/changing the OdorFree Checking the filter saturation Charcoal Filter operating hours indicator counter Before the set operating time has run The OdorFree Charcoal Filter is required out, you can check what percentage of for extraction mode. the time has elapsed.
Energy-saving tips This hood operates in a very efficient – Make sure that you switch the and energy-saving manner. The ventilation hood off after use. following will help you to save even If cooking vapors and odors still more energy when using it: need to be removed from the kitchen air after cooking, use the –...
Cleaning and care Special instructions for stainless Stainless steel housing steel surfaces General information Stainless steel surfaces can also be cleaned using a non-abrasive The surfaces and control buttons are stainless steel cleaner. susceptible to scratching and chipping. To prevent the surfaces from quickly Observe the following cleaning becoming dirty again, we recommend instructions.
Cleaning and care Removing the grease filters Grease filter The reusable metal grease filter in the appliance removes solid particles from the kitchen vapors (grease, dust, etc.) preventing soiling of the hood. A dirty filter is a fire hazard! Cleaning intervals Over longer periods of time, fat buildup on the grease filter hardens and makes...
Page 28
Select a program with a wash Do not use any of the following: temperature between 120°F (50°C) – Lime removers and 150°F (65°C). In a Miele dishwasher use the "Normal" – Abrasive powders or abrasive liquids program. – Aggressive all-purpose cleaners and...
It is fitted in the top of the ventilation hood. Charcoal filters are available from your Miele dealer or from Miele. See "Technical data" for the type and reference number. If the filter has been installed...
Cleaning and care When to change the OdorFree Disposing of the OdorFree Charcoal Charcoal Filter Filter Always replace the OdorFree Used OdorFree Charcoal Filters can Charcoal Filter whenever it no longer be disposed of with normal absorbs kitchen odors effectively. household waste.
Installation Before installation Before installing the appliance, read all of the information contained in this chapter and also in the "IMPORTANT SAFETY INSTRUCTIONS" section. Removing the protective film The housing components are covered by a protective film to prevent them from damage during transport.
Page 33
Installation a 1 vent collar for an exhaust duct 6 " (150 mm). b 1 reducing collar 5 screws ³/₁₆" x 2 ³/₈" (5 x 60 mm) for an exhaust duct 5 " (125 mm). 5 plugs ⁵/₁₆" x 2" (8 x 50 mm) c 1 non-return flap 3 washers ¹/₄"...
Installation Appliance dimensions The drawing is not to scale. a Extraction ducting upwards or to the rear. b Cut-out for ventilation hoods with hard-wired connection rather than a plug. c 7 7/8" (200 mm) cut-out ensures sufficient space through the wall for the extraction ducting to flex.
Please also observe the information contained in the "IMPORTANT SAFETY INSTRUCTIONS" section. Minimum distance S Cooking appliance Miele Non-Miele appliance appliance Electric Cooktops 24" (610 mm) Electric Barbeques and Fryers 26"...
Installation Installation recommendations Drilling diagram for wall mounting – When selecting an installation height, always take the user height into When drilling, please follow the consideration. Users should have directions contained on the ample space to work comfortably on accompanying installation sheet.
Installation Find the studs to the left and right Plywood backing of the mounting location by tapping The majority of the weight of the the wall or using a stud finder. installed ventilation system will be Mark a vertical cutting line along the supported by the lower retaining center of each stud.
Air venting – Make sure that all connections are WARNING: Danger of toxic fumes. secure and airtight. Gas cooking appliances release carbon monoxide that can be Remember that any constriction of harmful or fatal if inhaled. the airflow will reduce extraction To reduce the risk of fire and to performance and increase operating properly exhaust air, the exhaust...
Air venting Condensate trap Reducing Collar (optional accessory) If you would like to reduce the In addition to insulating the exhaust environmental impact of your ventilation duct, we recommend installing a system by limiting the CFM output the condensate trap to collect and Reducing Collar can be installed.
CSA C22.1-12, please consult a licensed electrician Canadian Electrical Code, Part I. or call Miele’s Technical Service Department. Alternatively, the hood can be hard- wired accordingly: WARNING: THIS APPLIANCE MUST...
Activating Con@ctivity 2.0 Activating the ventilation hood Installation of the Con@ctivity 2.0 stick The cooktop and ventilation hood must be turned off. In order for you to be able to use the Con@ctivity 2.0 function, the cooktop Press the delayed shut down button must be equipped with a Con@ctivity ...
Activating Con@ctivity 2.0 Activating the cooktop Activation failed While the ventilation hood is If a wireless connection cannot be searching for a wireless connection, established despite activation of the start activation on the cooktop. Con@ctivity function on the More information can be found in the ventilation hood and cooktop, the operating instructions for the...
Miele This service is available in USA only. dealer or Miele Technical Service. The telephone number for Miele is listed MieleCare, our Extended Service at the back of these instructions. Contract program, gives you the...
Technical data Blower motor 350 W Overhead cooktop lighting 3 x 3 W Total connected load* 359 W Supply voltage, frequency 120 V AC, 60 Hz Fuse 15 A Power cord length 2.5 ft (0.75 m) Weight 66 lbs (30 kg) Recirculation mode requires charcoal filter DKF 25-900 (optional accessory) Contains FCC ID: 2ACUWEI8800...