Operating and Installation instructions Rangehood DA 6290 W, DA 6290 W EXT en - AU To avoid the risk of accidents or damage to the appliance, it is essential to read these instructions before it is installed and used for the first time.
Caring for the environment Disposal of the packing Disposal of your old appliance material or machine The transport and protective packing Electrical and electronic appliances / has been selected from materials which machines often contain materials are environmentally friendly for disposal which, if handled or disposed of and can normally be recycled.
Any other usage is at the owner's risk. requirements. Inappropriate use Miele cannot be held liable for damage can, however, lead to personal injury resulting from incorrect or improper use and damage to property.
Faulty components must only be the data plate correspond to the on-site replaced by genuine Miele original electricity supply, otherwise the parts. The manufacturer can only appliance could be damaged. Consult guarantee the safety of the appliance a qualified electrician if in any doubt.
Page 7
These models may only be combined with a Miele external motor. This rangehood must not be installed and operated in mobile installations (e.g. on a ship).
Page 8
Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the extractor and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible.
Warning and Safety instructions Correct use Do not use the rangehood without the filters in place. This way you will Never use an open flame beneath avoid the risk of grease and dirt getting the rangehood. To avoid the danger of into the appliance and hindering its fire, do not flambé...
Safety regulations prohibit the fitting of a rangehood over solid fuel stoves. All ducting, pipework and fittings must be of non-flammable material. These can be obtained from Miele or from builders' merchants. The appliance must not be connected to a chimney or vent flue which is in use.
Description of the functions . . . air recirculation: The rangehood works with (available as an optional extra with a conversion kit and charcoal filter: see "Technical Data") . . . air extraction: The air is drawn in and cleaned first by The air is drawn in and cleaned by the the grease filter and then by a charcoal grease filters and directed outside.
Page 13
Description of the appliance a Telescopic extension piece o Operating hours touch control b Tower The grease filter symbol l for the operating controls lights up when the c Canopy grease filters need to be cleaned. d Control panel The charcoal filter symbol lights up e Grease filters when the charcoal filter used in recirculation mode needs to be...
Operation To switch the fan on s Automatic switch-off of the Intensive setting ^ Press the On/Off touch control s. You can set the Intensive setting so that The fan will come on at power level 2. it always only runs for 10 minutes The s symbol and the 2 will light up.
Operation Run-on function "5 ¢15" Cooktop lighting I It is advisable to run the fan for a few To switch the cooktop lighting on minutes after cooking has finished to neutralise any lingering odours in the The cooktop lighting can be switched air, whether you are using air extraction on and off independently of the fan.
Operation Glass edge feature lighting ] You have the option of saving one favourite colour to memory. ^ Press the control for the glass edge feature lighting ] to switch it on. To select the colour: This can be switched on and off ^ Select the rapid or slow colour independently of the fan or the change (colour setting e or f).
Operation Operating hours counter l ^ Press the run-on control 5 ¢15 and the operating hours control l at The number of hours the appliance has the same time. been in operation is stored in memory. The grease filter symbol l of the When the grease filter symbol l or the operating hours control and one of the charcoal filter symbol ...
Page 19
Operation Activating and altering the operating Reading the filter operating hours hours counter for the charcoal filter counter To check the percentage of time set (in recirculation mode) already used: ^ Press the On/Off sensor s to switch The charcoal filter is needed for the recirculation mode.
General notes A specially designed stainless steel detergent which prevents resoiling can The surfaces and controls are be purchased from Miele. Apply susceptible to scratches and sparingly with a soft cloth following the abrasion. Please observe the instructions on the packaging.
Cleaning and care Grease filters Controls The re-usable metal grease filters in the The controls may suffer appliance remove solid particles discolouration or damage if soiling is (grease, dust, etc.) from the kitchen left on them for too long. vapours, preventing soiling of the Remove soiling straight away.
^ Do not wash at more than 65 °C. If a Resetting the operating hours Miele dishwasher is being used, counter for the grease filters select the Sensor wash programme. After cleaning, the operating hours ^ Use a mild dishwasher detergent.
– it is no longer effective in absorbing Replacement charcoal filters can be kitchen odours. obtained from your Chartered Agent, It should, however, be replaced at least Miele or via the internet at every 6 months. www.miele-shop.com (depending on country). Used charcoal filters can be disposed See back cover for contact details, of with the normal household waste.
Cleaning and care Changing a halogen lamp ^ Before any cleaning or maintenance work, disconnect the rangehood from the mains supply. Ensure that: – it is switched off at the isolator, or – it is switched off at the wall socket and the plug is withdrawn, or –...
– your Miele Chartered Agent or – Miele You will find the telephone number and address of Miele on the back cover of the manual. Please quote the model and serial number when contacting Miele. These...
Open grill, deep fat fryer: 650 mm Gas cooktops: 650 mm If this rangehood is installed above a Miele Wok CS 1028 CombiSet appliance, a minimum safety distance of 760 mm must be maintained between the burner and the lower edge of the rangehood.
Page 28
Appliance dimensions Drill holes For a pre-installation on a back wall, refer to the drilling distances in the drawing above (screws ø 5 mm). If the rangehood is to be mounted directly to the wall, please refer to the installation manual.
Installation Dismantling Before installation, it is important to Should the appliance ever need to be read the information given on the dismantled, follow the installation following pages as well as the instructions in reverse order as "Appliance dimensions" and the described on the installation sheet.
Page 31
Installation a 3 protective sheets for use when fitting the tower. b 1 exhaust connection for exhaust 2 x M 6 self-tapping nuts ducting C 150 mm. for securing the appliance. c 1 reducing collar for exhaust ducting C 125 mm. d 1 non-return flap for fitting into the exhaust connection 2 screws 3.9 x 7.5 mm...
Connection for air extraction – Only use smooth pipes or flexible Important: To avoid the danger of hoses made from non-flammable toxic fumes, please observe the materials for the extraction ducting. Warning and Safety instructions. – When using an external motor, make This is especially crucial when using sure that the exhaust ducting is the rangehood at the same time as...
Connection for air extraction Condensate trap – If the exhaust air is to be ducted into the open air, the installation of a (optional accessory) telescopic wall vent or roof vent (available as an optional accessory) is recommended. – If the exhaust air is to be ducted into a vent flue, the ducting must be directed in the flow direction of the flue.
Connection for air extraction Silencer ...with air extraction: (optional accessory) The silencer not only reduces noise from the motor outside the house, but also sounds from outside (e.g. traffic noise). For this reason the silencer must be positioned as close as possible to the ducting exit a.
Electrical connection If the switch is not accessible after All electrical work should be installation, an additional means of undertaken by a suitably qualified disconnection must be provided for all and competent person in strict poles. accordance with current national For extra safety, it is advisable to install and local safety regulations.
Operation with Control module DSM 400 The Miele DSM 400 can be used to The components of the central combine the rangehood with other extraction system are not supplied as components. standard by Miele. It enables the following: If in any doubt, the advice of a competent builder must be sought.