hit counter code
Miele SmartLine CSDA 7000 FL Operating And Installation Instructions
Miele SmartLine CSDA 7000 FL Operating And Installation Instructions

Miele SmartLine CSDA 7000 FL Operating And Installation Instructions

Downdraft extractor

Advertisement

Operating and installation instructions
SmartLine downdraft extractor
To prevent the risk of accidents or damage to the appliance, it is
essential to read these instructions before it is installed and used for
the first time.
en-AU, NZ
M.-Nr. 11 037 890

Advertisement

Table of Contents
loading

Summary of Contents for Miele SmartLine CSDA 7000 FL

  • Page 1 Operating and installation instructions SmartLine downdraft extractor To prevent the risk of accidents or damage to the appliance, it is essential to read these instructions before it is installed and used for the first time. en-AU, NZ M.-Nr. 11 037 890...
  • Page 2: Table Of Contents

    Contents Warning and Safety instructions................ 4 Caring for the environment ................ 14 Overview.......................  15 Downdraft extractor....................15 Controls / Indicators....................16 Cleaning the SmartLine appliance for the first time ........ 17 Description of the functions ................ 18 Tips on saving energy .................. 19 Operation......................
  • Page 3 Contents Worktop cut-out for flush-fit installation............ 38 Flush-fit installation.....................  41 Spacer bars...................... 42 Installation...................... 44 Preparing the worktop................... 44 Fitting the spacer bars ..................45 Installing the downdraft extractor................46 E-box ........................47 Connection for air extraction ................ 50 Electrical connection .................. 52 Service........................
  • Page 4: Warning And Safety Instructions

    They contain important notes on the safety, installation, use and maintenance of the appliance. Miele cannot be held liable for non- compliance with these instructions. Keep these instructions in a safe place and ensure that all users are familiar with the contents.
  • Page 5  The downdraft extractor must only be used to extract vapours and remove odours from cooking. Any other usage is at the owner's risk. Miele cannot be held liable for damage resulting from incorrect or improper use or operation. ...
  • Page 6 Warning and Safety instructions Safety with children  Young children must be kept away from the downdraft extractor.  Older children may only use the downdraft extractor without supervision if they have been shown how to use it in a safe manner. They must be aware of the potential dangers caused by incorrect operation.
  • Page 7  Unauthorised installation, maintenance and repairs can cause considerable danger for the user. Installation, maintenance and repairs must only be carried out by a Miele authorised technician.  The downdraft extractor must only be installed and operated in combination with those SmartLine appliances and cooktops specified by Miele.
  • Page 8 The manufacturer's warranty will be invalidated if the appliance is not repaired by a Miele approved service technician.  Faulty components must only be replaced by genuine Miele spare parts. The manufacturer can only guarantee the safety of the appliance when Miele replacement parts are used.
  • Page 9 Warning and Safety instructions  During installation, maintenance and repair work, the downdraft extractor must be completely disconnected from the mains electricity supply. It is only completely isolated from the electricity supply when: – the mains circuit breaker is switched off, or –...
  • Page 10 Warning and Safety instructions Using at the same time as other heating appliances that depend on the air from the room  Warning - danger of toxic fumes! Great care should be taken when using the downdraft extractor at the same time and in the same room or area of the house as another heating appliance which depends on the air in the room.
  • Page 11 Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the downdraft extractor and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible.
  • Page 12 Warning and Safety instructions Correct use  Never use an open flame beside the downdraft extractor. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the downdraft extractor could draw flames into the filter.
  • Page 13 There is a risk of fire if cleaning is not carried out as described in these operating instructions. Accessories  Use only genuine original Miele spare parts. If spare parts or accessories from other manufacturers are used, the warranty will be invalidated, and Miele cannot accept liability.
  • Page 14: Caring For The Environment

    Caring for the environment Disposal of the packing Disposing of your old material appliance The transport and protective packaging Electrical and electronic appliances has been selected from materials which often contain valuable materials. They are environmentally friendly for also contain specific materials, disposal, and can normally be recycled.
  • Page 15: Overview

    Overview Downdraft extractor a FlameGuard b Grease filter c Main unit with controls d Casing e Moisture collection tray f Air duct g Fan h E-box...
  • Page 16: Controls / Indicators

    Overview Controls / Indicators a For switching the downdraft extractor on/off b Numerical keybank for setting the power level...
  • Page 17: Cleaning The Smartline Appliance For The First Time

    Cleaning the SmartLine appliance for the first time  Please stick the extra data plate for the appliance supplied with this documentation in the space provided in the “Service” section of this booklet. Alternatively, the additional label can be stuck near the appliance if the appliance markings are not visible after installation.
  • Page 18: Description Of The Functions

    Description of the functions Depending on the model of the downdraft extractor, the following options are available: Air extraction mode The air is drawn in and cleaned by the grease filter and directed outside. Recirculation mode (DUU 1000(-1) conversion kit required) The air is drawn in and cleaned by the grease filter.
  • Page 19: Tips On Saving Energy

    Tips on saving energy This downdraft extractor operates very efficiently and economically. The following will help you to save even more energy when using it: – It is important to ensure that the kitchen is well ventilated during operation. In extraction mode if there is insufficient air flow, the downdraft extractor cannot operate efficiently and this causes increased operating...
  • Page 20: Operation

    Operation FlameGuard Setting/Changing the power level For light to heavy cooking vapours and odours, select from power levels 1 to 3. For short periods of cooking food with intensive vapours and a strong aroma, e.g. when searing meat, select Booster setting B.
  • Page 21: Run-On Time

    Operation Run-on time In order to rid kitchen air of steam and odours, the downdraft extractor continues to run for 5 minutes on the power level that was set last. The power level is gradually reduced during the run-on time. The current power level pulsates during the run-on time.
  • Page 22: Cleaning And Care

    Cleaning and care  Allow the SmartLine appliance to Risk of burning due to hot cool down before cleaning. surfaces. The surfaces will be hot after use.  Clean the SmartLine appliance and Switch the downdraft extractor and accessories after each use. the cooking elements off.
  • Page 23: Ceramic Surface

     Clean and dry the moisture collection  Then clean the ceramic glass surface tray. with the Miele ceramic and stainless  Clean and dry the accessible inside steel cooktop cleaner (see “Optional of the downdraft extractor.
  • Page 24: Grease Filter

    Cleaning and care  Select a dishwasher programme with Grease filter a wash temperature between 50 °C The reusable metal grease filter and 65 °C. removes solid particles from kitchen vapours (grease, dust, etc.) and Depending on the detergent used, therefore prevents soiling of the cleaning the grease filter in a downdraft extractor.
  • Page 25: Problem Solving Guide

    Miele. This will save you time and money because you will not need a service call. If, after reading this guide, you cannot remedy the problem yourself, please call Miele (see back cover for details).
  • Page 26: Optional Accessories

    Original Miele ceramic and the Miele online shop. stainless steel cooktop cleaner They can also be ordered directly from 250 ml Miele (see end of this booklet for contact details). Removes heavy soiling, limescale deposits and aluminium residues. Original Miele all purpose microfibre cloth Removes finger marks and light soiling.
  • Page 27: Safety Instructions For Installation

    (e.g. a drawer) or be subject to mechanical loads which could damage it.  Combination with gas appliances Only Miele CS 7xxx gas appliances may be installed next to the downdraft extractor.  Carefully observe the safety clearances listed on the following pages.
  • Page 28: Installation Notes

    Installation notes Tiled worktop All dimensions in this instruction booklet are given in mm. Installation of surface- mounted appliances Sealing between the SmartLine appliance and the worktop Grout lines  and the hatched area underneath the SmartLine appliance frame must be smooth and even. If they are not, the SmartLine appliance will not sit flush with the worktop and the sealing strip underneath the top part of...
  • Page 29: Flush-Fit Installation

    Installation notes Natural stone worktops Flush-fit installation The SmartLine appliance is set directly Flush-fit installation is only possible in in the cut-out. natural stone (granite, marble), solid wood and tiled worktops. For Solid wood worktops, tiled worktops, installation in worktops made of other glass worktops materials, please consult the relevant The SmartLine appliance is set on a...
  • Page 30: Installing Several Smartline Appliances

    Installation notes Installing several SmartLine Moisture collection tray appliances The downdraft extractor must be installed in such a way that the moisture The gaps between the individual collection tray is freely accessible and SmartLine appliances are sealed with a can be removed for cleaning. silicone sealant that is heat-resistant to at least 160 °C.
  • Page 31: Installation Examples

    Installation notes Installation examples Recirculation mode Air extraction mode...
  • Page 32: Building-In Dimensions

    Building-in dimensions Installation of surface-mounted cooktops a Front b Fan (in the plinth on the floor) c Air duct d E-box...
  • Page 33: Flush-Fit Installation

    Building-in dimensions Flush-fit installation a Front d 12 mm wooden frame (not supplied, for detailed illustrations, see b Fan (in the plinth on the floor) “Worktop cut-out for flush-fit c Stepped cut-out (for detailed installation”) illustrations, see “Worktop cut-out for e Air duct flush-fit installation”) f E-box...
  • Page 34: Worktop Cut-Out For Surface-Mounted Installation

    Worktop cut-out for surface-mounted installation ß R 4 Information for calculating the cut-out The SmartLine appliances overlap the worktop by 10 mm. When installing several SmartLine appliances, a distance of 2 mm must be observed between the individual SmartLine appliances. Calculating cut-out dimension B 1 appliance = width of the appliance minus 10 mm on the right, minus 10 mm on the left.
  • Page 35 Worktop cut-out for surface-mounted installation Installation with a downdraft extractor Sample combinations Number x width [mm] Dimension  B Cooking Downdraft [mm] appliances extractor 1 X 378 1 X 120 2 X 378 1 X 120 1 x 378 2 X 120 1224 1 x 620 3 X 378 2 X 120 1362 2 x 378 2 X 120 1604 1 x 620 4 X 378 2 X 120 1742 1 X 620 2 X 120...
  • Page 36 Worktop cut-out for surface-mounted installation Installation without a downdraft extractor Sample combinations Number x width [mm] Dimension B [mm] Cooking appliances 1 X 378 2 X 378 1 x 378 1 x 620 3 X 378 1118 2 x 378 1360 1 x 620 4 X 378 1498...
  • Page 37: Surface-Mounted Installation

    Surface-mounted installation Granite and marble worktops If the worktop is more than 24 mm deep, it must be cut out underneath You will need heavy-duty double- on the building-in side on the right or sided tape (not supplied) to secure the left-hand side.
  • Page 38: Worktop Cut-Out For Flush-Fit Installation

    Worktop cut-out for flush-fit installation ß R 4 +0,5 +0,5 Natural stone worktop Wooden worktop Information for calculating the cut-out The SmartLine appliances overlap the worktop by 10 mm. When installing several SmartLine appliances, a distance of 2 mm must be observed between the individual SmartLine appliances. Calculating cut-out dimension A 1 SmartLine appliance = width of the appliances plus 2 mm on the right, plus 2 mm on the left.
  • Page 39 Worktop cut-out for flush-fit installation Installation with a downdraft extractor Sample combinations Number x width [mm] Dimension Dimension  A  B Cooking Downdraft [mm] [mm] appliances extractor 1 X 378 1 X 120 2 X 378 1 X 120 1 x 378 2 X 120 1248 1224 1 x 620 3 X 378 2 X 120 1386 1362 2 x 378 2 X 120 1628 1604 1 x 620 4 X 378...
  • Page 40 Worktop cut-out for flush-fit installation Installation without a downdraft extractor Sample Number x width Dimension A Dimension B combinations [mm] [mm] [mm] Cooking appliances 1 X 378 2 X 378 1 x 378 1004 1 x 620 3 X 378 1142 1118 2 x 378 1384 1360 1 x 620 4 X 378 1522 1498...
  • Page 41: Flush-Fit Installation

    Flush-fit installation Granite and marble worktops If the worktop is more than 28 mm deep, it must be cut out underneath You will need heavy-duty double- on the building-in side on the right or sided tape (not supplied) to secure the left-hand side.
  • Page 42: Spacer Bars

    Spacer bars When installing several SmartLine appliances, an additional spacer bar must be fitted in between the individual appliances. The clips supplied with the spacer bars are only required for installing the CSDA 7000 FL. Installing 3 appliances and 2 spacer bars Installation of surface-mounted appliances Flush-fit installation...
  • Page 43 Spacer bars Spacer bars for the downdraft extractor Surface-mounted installation a Brackets Flush-fit installation a Brackets...
  • Page 44: Installation

    Installation Preparing the worktop  Create the worktop cut-out. Remember to maintain the minimum safety distances (see “Safety distances”).  Seal the cut surfaces of wooden worktops with a suitable heat- resistant sealant to avoid swelling caused by moisture. The sealant must be temperature-resistant.
  • Page 45: Fitting The Spacer Bars

    Installation Granite and marble worktops Fitting the spacer bars Use the middle screw holes if one of the You will need heavy-duty double- following SmartLine appliances is sided tape (not supplied) to secure the installed to the right or left of the spacer spacer bars.
  • Page 46: Installing The Downdraft Extractor

    Installation Installing the downdraft extractor The downdraft extractor can be installed with the connector for the air duct on either the right or the left-hand side.  Remove the moisture collection tray from the casing.  Fasten the casing from the inside with a Connector for air duct on the right the screws ...
  • Page 47: E-Box

    Installation E-box The connection cable of the switching system must be of the correct type and cross-sectional area in strict accordance with current national and local safety regulations and must not exceed 2.0 m in length. The switching system must be equipped with a potential-free contact suitable for 230 V, 1 A.
  • Page 48 Installation  Loosen the lug and pull the plug out. Connecting the e-box  Connect the fan power cable and fan control cable to the e-box and the fan.  Connect the control unit cable to the e-box. The socket positions are designed in such a way that they cannot be mixed ...
  • Page 49 Installation Sealing the gaps  Seal the gaps between the individual SmartLine appliances, and between the flush-fit SmartLine appliances and the worktop, with a silicone sealant that is heat-resistant to at least 160 °C. Unsuitable sealant can damage natural stone. For natural stone worktops and natural stone tiles, only use silicone sealant that is specially formulated for natural stone.
  • Page 50: Connection For Air Extraction

    Connection for air extraction – For the rectangular ducting, Miele  Before installation, it is important recommends not to exceed a to read the following information. maximum total ducting length of 5 m, This is particularly crucial when using with a maximum number of three the downdraft extractor at the same bends.
  • Page 51 Connection for air extraction  If the exhaust air is to be ducted into a flue, the ducting must be directed in the flow direction of the flue.  If ducting is to be laid horizontally, it must be laid with a downwards sloping gradient.
  • Page 52: Electrical Connection

    Residual current device dangerous. Miele cannot be held liable for unauthorised work. For extra safety, it is advisable to Miele cannot be held liable for protect the SmartLine appliance with a damage or injury (e.g. electric shock) suitable residual current device (RCD) caused by the lack of or inadequacy with a trip range of 30 mA.
  • Page 53 When replacing the mains connection cable, it must be replaced with cable type H 05 VV-F by a Miele authorised service technician or a suitably qualified and competent electrician. These cables are available from Miele.
  • Page 54: Service

    Service Contact in case of fault In the event of any faults which you cannot remedy yourself, please contact Miele. Contact information for Miele can be found at the end of this booklet. Please quote the model and serial number of your appliance when contacting Miele.
  • Page 55 Miele Experience Centre South Melbourne: Freemans Bay, Auckland 1011 206-210 Coventry Street South Melbourne, VIC 3205 Miele Experience Centre Auckland: Miele Experience Centre and Office Sydney: 8 College Hill 3 Skyline Place Freemans Bay, Auckland 1011 Frenchs Forest, NSW 2086 Telephone:...
  • Page 56 CSDA 7000 FL en-AU, NZ M.-Nr. 11 037 890 / 01...

Table of Contents