hit counter code
Table of Contents

Advertisement

Quick Links

Operating and Installation
Instructions
Ventilation Hood
To prevent accidents and damage to the appliance, you must read
these instructions before installing the appliance and using it for the
first time.
en-US
M.-Nr. 12 253 870

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA6698DSS

  • Page 1 Operating and Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr. 12 253 870...
  • Page 2: Table Of Contents

    Description of functions ................... 16 Before using for the first time ................17 Selecting extraction mode or recirculation mode..........17 Setting up Miele@home ..................17 Connecting via the app .................. 18 Connecting via WPS ..................19 Signing out of WiFi (reset to factory settings) ..........20 Setting up Con@ctivity ..................
  • Page 3 Contents Cleaning and care ..................... 34 Stainless steel housing..................34 Important information for appliances with stainless steel surfaces ....34 Important information for appliances with lacquered housing....... 34 Grease filters ....................... 35 Replacing the grease filter................36 OdorFree Charcoal Filter ..................37 Resetting the filter saturation indicator for the charcoal filters.......
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user.
  • Page 5  Unauthorized installation, maintenance, and repairs can cause considerable danger for the user. Installation, maintenance, and repairs must only be carried out by a Miele authorized technician.  A damaged ventilation hood can be dangerous. Always check for visible signs of damage. Never use a damaged ventilation hood.
  • Page 6 The function and operation of the protective measures provided in the domestic electrical installation and in this Miele product must also be maintained in isolated operation or in operation that is not synchronized with the grid power supply, or these measures must be replaced by equivalent measures in the installation.
  • Page 7 IMPORTANT SAFETY INSTRUCTIONS  Only open the housing as described in the enclosed “Installation diagram” and in the “Cleaning and care” section of this manual. Under no circumstances should any other parts of the housing be opened. Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operation faults.
  • Page 8 IMPORTANT SAFETY INSTRUCTIONS  Open flames are a fire hazard. The use of an open flame under the ventilation hood is not permitted. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the ventilation hood could draw flames into the filter.
  • Page 9 IMPORTANT SAFETY INSTRUCTIONS  Always turn the ventilation hood on whenever a burner is in use to prevent damage from condensation.  Overheated oil and fat can ignite, causing fire damage to the ventilation hood. Do not leave cookware, pans, and deep-fat fryers unattended when cooking with oil or fat.
  • Page 10 IMPORTANT SAFETY INSTRUCTIONS Proper installation  WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: - a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • Page 11 The steam can reach the electrical components and cause a short circuit. Accessories and parts  Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty may become void.  Defective components should be replaced by Miele original parts only.
  • Page 12 IMPORTANT SAFETY INSTRUCTIONS  Miele will guarantee to supply functional parts for a minimum of 10 years and up to 15 years following the discontinuation of your ventilation unit. FCC Declaration of Conformity  These devices comply with FCC Rules Part 15. This equipment...
  • Page 13: Caring For The Environment

    Consult with local authorities, dealers or Miele in order to dispose of and recycle electrical and electronic appliances. Miele assumes no responsibility for deleting any personal data left on the appliance being disposed.
  • Page 14: Guide To The Ventilation Hood

    Guide to the ventilation hood...
  • Page 15 Guide to the ventilation hood a Telescopic extension piece b Duct cover c Canopy d Controls e Grease filter f Spacer frame The spacer frame creates a shadow gap between the chimney and the ceiling. The ventilation hood can be installed with or without the spacer frame. g Recirculation vents Only for recirculation mode h Overhead lighting...
  • Page 16: Description Of Functions

    Description of functions The following functions are available on Recirculation mode your ventilation hood, depending on the The recirculation mode requires a model: recirculation kit and OdorFree Charcoal Filter (available as optional accessories, Extraction mode see “Technical Data” for more information) The air is drawn in and cleaned by the grease filters and directed outside.
  • Page 17: Before Using For The First Time

    Miele app.  Switch off the blower and the lighting. If your Miele cooktop is connected to a  Touch the delayed shutdown home WiFi network, you can control the control  and the charcoal filter ventilation hood automatically via the control ...
  • Page 18: Connecting Via The App

    Before using for the first time Miele App Connecting via the app The Miele App is available to download The Miele app can be used to connect free of charge from the Apple App to your network. ® Store or from the Google Play Store™.
  • Page 19: Connecting Via Wps

    Before using for the first time  Switch the ventilation hood off. Connecting via WPS Your WiFi router must support WPS (WiFi Protected Setup).  Press and hold the B control.  Switch the ventilation hood off.  Touch the lighting control  at the ...
  • Page 20: Signing Out Of Wifi (Reset To Factory Settings)

    WPS to your The ventilation hood is ready for router quickly enough. Repeat the steps disconnection during the next two above. minutes. Tip: If your WiFi router does not support WPS, please connect via the Miele app.
  • Page 21: Setting Up Con@Ctivity

    Con@ctivity is the direct communication  Touch the 1 control. system between an induction Miele cooktop and a Miele ventilation hood. It enables the ventilation hood to operate automatically depending on the 2 will light up constantly, 3 will flash on operational state of a Miele cooktop and off.
  • Page 22: Con@Ctivity Via The Home Wifi Network (Con@Ctivity 3.0)

    Con@ctivity function via a WiFi connection (Con@ctivity 3.0) or Prerequisite: via a wireless connection (Con@ctivity - WiFi enabled Miele cooktop 2.0). If you do not have a home network, you Con@ctivity via the home WiFi can establish a direct connection network (Con@ctivity 3.0)
  • Page 23: Reattempting The Connection

    Con@ctivity with direct wireless cooktop. For more details, see the connection (Con@ctivity 2.0) cooktop operating instructions. Required: - Con@ctivity 2.0 enabled Miele induction cooktop When successfully connected, 2 and 3 will light up constantly.  Quit connection mode on the ventilation hood by touching the delayed shutdown control .
  • Page 24 Before using for the first time Installing the Con@ctivity 2.0 stick Activating the ventilation hood  See the relevant installation  The cooktop and ventilation hood instructions provided with the must be switched off. Con@ctivity 2.0 stick. Activating the wireless connection ...
  • Page 25 Before using for the first time Finishing activation on the ventilation hood  Touch the B control to activate Con@ctivity 2.0. When successfully connected, B will go out, and 2 and 3 will light up constantly. 2 will light up constantly, 3 will flash on and off.
  • Page 26 Before using for the first time Activation failed If a wireless connection cannot be established despite activation of the  Touch the 1 control to deactivate Con@ctivity function on the ventilation Con@ctivity 2.0. hood and cooktop, the function must first be deactivated and then reactivated on both appliances.
  • Page 27: Operation (Automatic Mode)

    Operation (Automatic mode) When Con@ctivity is active, the ventilation hood always operates in automatic mode (see “Before using for the first time – Setting up Con@ctivity”). If you wish to operate the ventilation hood manually; see “Operation (Manual mode) – Cooking without Examples for power levels 1 to B Con@ctivity”.
  • Page 28: Temporarily Exiting Automatic Mode

    Operation (Automatic mode) Resuming Automatic mode Switching off The ventilation hood resumes  Turn off all burners. Automatic mode: Over the next few minutes, the - If the ventilation hood has not been ventilation hood blower setting will used for a period of approx. decrease one level at a time until the 5 minutes after the manual selection hood eventually turns off.
  • Page 29: Operation (Manual Mode)

    Operation (Manual mode) Cooking without Con@ctivity Selecting the delayed (Manual mode) shutdown time The ventilation hood can be operated It is advisable to run the blower for a manually if: few minutes after cooking has finished. This helps to neutralize any lingering - The Con@ctivity function is not vapors and odors in the air.
  • Page 30: Power Management

    Operation (Manual mode)  With the lighting switched on, press - the lighting control , and hold the lighting control . The - the 1 control, and then brightness will gradually dim until you release the control. - the lighting control .  To increase the brightness, press and When power management is turned on, hold the lighting control ...
  • Page 31: Operation (Automatic And Manual Modes)

    Operation (Automatic and Manual modes)  Switch off the blower and the lighting. Filter saturation indicator  Touch the delayed shutdown The ventilation hood registers the length control  and the grease filter of time it has been operated. control  at the same time. The filter saturation indicators show The grease filter symbol ...
  • Page 32: Adjusting Or Deactivating The Filter Saturation Indicator For The Charcoal Filter

    Operation (Automatic and Manual modes) Adjusting or deactivating the filter Checking the filter saturation saturation indicator for the charcoal indicator filter Before the set operating time has run The charcoal filter is needed for out, you can check what percentage of recirculation mode.
  • Page 33: Energy-Saving Tips

    Energy-saving tips This hood operates in a very efficient to capture cooking vapors that and energy-saving manner. The have already been distributed following will help you to save even throughout the kitchen. more energy when using it: – Make sure that you switch off the hood after use.
  • Page 34: Cleaning And Care

    To prevent the surfaces from quickly Stainless steel housing becoming dirty again, we recommend treating them with a stainless steel care General information product (available from Miele).  The surfaces and control buttons Important information for appliances are susceptible to scratching and with lacquered housing chipping.
  • Page 35: Grease Filters

    Cleaning and care Removing the grease filters Grease filters  When handling the grease filter,  Risk of fire be careful not to drop it. Oversaturated grease filters are a fire This can result in damage to the filter hazard. and the cooktop below.
  • Page 36: Replacing The Grease Filter

     Use a commonly available household the grease filter control  for approx. dishwashing detergent. 3 seconds, until only the 1 is flashing.  In a Miele dishwasher use the The grease filter symbol  goes out. “Normal” program. When cleaning the grease filters before...
  • Page 37: Odorfree Charcoal Filter

     Used charcoal filters can be disposed of with normal household waste. Charcoal filters are available to order via the Miele Web Store (see end of this booklet for contact details), or from your Miele dealer. The charcoal filters are listed under “Technical data”...
  • Page 38: Customer Service

    In the event of a fault which you cannot remedy yourself, please contact your Miele dealer or Miele Customer Service. You can book a Miele Service Call online at www.miele.com/service. Contact information for Miele Customer Service can be found at the end of this document.
  • Page 39: Installation

    *INSTALLATION* Installation Before installation  Before installation, it is important to read the information contained in 4 extension piece holders this chapter and in the “IMPORTANT for aligning and securing the telescopic SAFETY INSTRUCTIONS” chapter. chimney Installation parts 4 screws, M4 x 8.5 mm for securing the extension piece holders.
  • Page 40: Appliance Dimensions

    *INSTALLATION* Installation Appliance dimensions a Mounting area for the exhaust ducting and power cable. In recirculation mode, only the power cord is required. b Possible height range for appliance in extraction mode c Possible height range for appliance in recirculation mode d Alternative installation with spacer frame e Air vent positioned at the top for recirculation...
  • Page 41: Distance Between Cooktop And Ventilation Hood (S)

    Please also observe the information contained in the “IMPORTANT SAFETY INSTRUCTIONS” section. Minimum distance S Cooking appliance Miele Non-Miele appliance appliance Electric Cooktops 24" (610 mm) Electric Barbeques and Fryers 26"...
  • Page 42: Installation Recommendations

    *INSTALLATION* Installation Installation recommendations Structural support - A distance of at least 26" (660 mm) is recommended above electric cooktops to provide more workspace and easier cooking under the hood. - When selecting an installation height, always take the user height into consideration.
  • Page 43 *INSTALLATION* Installation " "  For extraction mode: - Lay the vent duct and feed it down through the ceiling in the area shown. A section of flexible vent duct approx. 28" (700 mm) long is needed between the ceiling and the dai3435aus ventilation hood’s vent socket.
  • Page 44 *INSTALLATION* Installation  Use a knife to release the four spacers and the two covers from the spacer frame supplied.  Drill four holes  ³/₈“ (10 mm), approx. 4 ¹/₂” (115 mm) deep for the plugs supplied.  Use the spacer frame as a drilling ...
  • Page 45 *INSTALLATION* Installation The spacer frame can be installed between the chimney and the ceiling. This creates a shadow which gives the illusion of a gap between the ceiling and the chimney. This is useful if the ceiling  Mount the spacer frame onto the is not level or is uneven.
  • Page 46 *INSTALLATION* Installation  Hang the installation frame on the  Align the installation frame and four screws. The front of the frame is secure it with the screws. marked with a “V”. The spacers, which were removed  If using the spacer frame, place the from the spacer frame at the start, two covers into the fixing holes.
  • Page 47 *INSTALLATION* Installation  Holding the installation frame securely, remove the two fixing screws and extend the installation frame to its maximum length.  Replace the screws. The directional unit from recirculation kit DUI 32 (optional accessory) is installed for recirculation mode (RM): ...
  • Page 48 *INSTALLATION* Installation  Secure the hose to the directional unit socket using a hose clip.  Check that the hose is held securely.  Push the telescopic chimney over the installation frame: - with the recirculation grilles at the bottom for extraction mode (AE), - with the recirculation grilles at the top for recirculation mode (RM).
  • Page 49 *INSTALLATION* Installation  Fit the four telescopic chimney  Bend back the two retaining tabs. clamps. When the screws are  Push the chimney over the telescopic tightened, the clamps spread out and extension piece and bend the push the telescopic expansion piece retaining tabs outward again to upwards.
  • Page 50 *INSTALLATION* Installation A non-return flap is supplied with the hood or is already fitted in the exhaust socket of the motor unit (depending on model).  With vented mode (AE) insert the non-return flap in the exhaust socket if your ducting system is not equipped with one.
  • Page 51 *INSTALLATION* Installation  Connect the power cord. See “Electrical connection.”  Unscrew both screws from the installation frame again.  Slide the vent duct onto the vent The canopy can now be adjusted to the socket and secure it (using a hose desired height, observing the clip, for example).
  • Page 52 *INSTALLATION* Installation  Raise the canopy to the desired  Hold the chimney securely, bend height and secure it with the screws. back the retaining tabs and carefully lower it. The chimney will locate in the cut-out in the canopy.
  • Page 53 *INSTALLATION* Installation  With recirculation mode (RM) ventilation hoods, insert the OdorFree Charcoal Filter.  Remove the grease filters from the hood.  Insert the safety screw on the inside.  Carefully remove the protective foil from the grease filters. ...
  • Page 54: Air Venting

    “Appliance dimensions”). This applies in particular when using flat ducting. If the exhaust is ducted through an outside wall, a Miele wall vent or roof - The ducting should be as short and vent (available as an optional straight as possible.
  • Page 55: Condensate

    If the ducting is to run through cool the direction of airflow. rooms or ceiling space, for example, the significant variations in temperature Miele will not accept warranty claims between the different areas can cause for any functional defects or damage condensate to form. Insulate the caused by inadequate ducting.
  • Page 56: Electrical Connection

    If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or call Miele’s Technical Service Department. WARNING: THIS APPLIANCE MUST BE GROUNDED The strain relief must be used to ensure...
  • Page 57: Technical Data

    Technical data Blower motor 350 W Overhead lighting 4 x 3 W Total connected load 362 W Supply voltage, frequency 120 V AC, 60 Hz Fuse 15 A Weight 77 lbs (35 kg) WiFi module Frequency range 2.400–2.4835 GHz Maximum transmission power < 100 mW ZigBee® module Frequency band 2.405–2.48 GHz Maximum transmission power <...
  • Page 59 Customer Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Headquarters and Miele Centre Princeton, NJ 08540 161 Four Valley Drive www.mieleusa.com Vaughan, ON L4K 4V8 www.miele.ca Customer Support Phone: 888-99-MIELE (64353) Customer Care Centre info@mieleusa.com...
  • Page 60 DA 6698 D en-US M.-Nr. 12 253 870 / 01...

Table of Contents