Page 1
Operating and installation instructions Cooker hood DA 2250, DA 2250 EXT DA 2270, DA 2270 EXT DA 2210 en - GB To avoid the risk of accidents or damage to this appliance, it is essential to read these instructions before it is installed and used for the first time.
Caring for the environment Disposal of the packing material Disposal of your old appliance The transport and protective packing Electrical and electronic appliances has been selected from materials which often contain materials which, if are environmentally friendly for handled or disposed of incorrectly, disposal, and should be recycled.
Any other usage is not supported by requirements. Inappropriate use the manufacturer and could be can, however, lead to personal injury dangerous. Miele cannot be held liable and damage to property. for damage resulting from incorrect or improper use or operation.
Faulty components must only be the appliance could be damaged. replaced by genuine Miele original Consult a qualified electrician if in any parts. The manufacturer can only doubt. guarantee the safety of the appliance...
Page 6
These models may only be combined with a Miele external motor. This appliance must not be used in a non-stationary location (e.g. on a ship). Great care should be taken when...
Page 7
Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the cooker hood and the heating appliance are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible.
Warning and Safety instructions Correct use Do not use the cooker hood without the filters in place. This way you will Never use an open flame beneath avoid the risk of grease and dirt getting the cooker hood. To avoid the danger into the appliance and hindering its of fire, do not flambé...
Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves. All ducting, pipework and fittings must be of non-flammable material. These can be obtained from the Miele Spare Parts department or from builders' merchants. The appliance must not be connected to a chimney or vent flue which is in use.
Special accessory for recirculation for the first time. mode The touch control is used to reset the DA 2250, DA 2270: 2 filters operating hours counter every time the DA 2210: 4 filters charcoal filters are replaced (see "Cleaning and care").
Operation Joystick To select a power level ^ Press the joystick repeatedly to the This is used to operate the fan settings and the lighting. right to select a higher power level, and to the left to select a lower power To switch the fan on level.
Operation Run-on option Automatic switch-off of the Intensive setting It is advisable to run the fan for a few You can set the Intensive setting so that minutes after cooking has finished to it only runs for 10 minutes before neutralise any lingering odours in the air, whether you are using air extraction reverting automatically to level III.
Operation To switch the hob lighting on To switch the hob lighting off ^ Press the joystick again once to the The hob lighting can be switched on and off independently of the fan. rear or to the front to switch it off. Safety cut-out Should the cooker hood be left on, the fan will switch off automatically after 10...
Operation Filter operating hours counter Reading the grease filter operating hours counter The number of hours the appliance has been in operation is stored in memory. To check the percentage of time set already used: The operating hours counter tells you ^ Switch the fan on with the joystick.
Page 17
Operation Altering the grease filter operating hours counter The operating hours counter for the grease filter is set at the factory for 30 hours. This can be lengthened or shortened to suit the type of cooking you do. You can choose 20, 30, 40 or 50 hours.
Page 18
Operation Activating and altering the charcoal filter operating hours counter (in recirculation mode) The charcoal filters must be fitted for the cooker hood to be used in recirculation mode. On delivery, the operating hours counter for the charcoal filter is deactivated. For recirculation mode, the operating hours counter needs to be set to suit ^ Use the joystick to select the time...
Page 19
Operation Resetting the charcoal filter Reading the charcoal filter operating operating hours counter hours counter To check the percentage of time set already used: ^ Switch the fan on with the joystick. The indicator lamp for the charcoal filter control will light up after the cooker hood has operated for the number of hours set.
Cleaning and care A range of Miele branded cleaning and Do not use: conditioning agents are available to – cleaning agents containing soda, order through your Miele Dealer / acids, chlorides or solvents, Chartered Agent, the Miele Spare Parts Department, or via the internet on –...
Page 21
Make sure that the spray arm can move freely. ^ Do not wash at more than 65° C. If a Miele dishwasher is being used, select the Sensor wash programme. ^ Use a mild dishwasher detergent. ^ To take out the grease filters, release...
DA 2250, DA 2270: 2 charcoal filters DA 2210: 4 charcoal filters New filters can be purchased from your Miele dealer or from the Miele Spare Parts Department.
Page 23
Cleaning and care Always replace the charcoal filters im- mediately if – the indicator lamp for the charcoal filter control lights up, – they are no longer effective in absorbing kitchen odours. They should, however, be replaced at least every 6 months. Used charcoal filters can be disposed of with the normal household waste.
Cleaning and care Changing a halogen lamp Before any cleaning or maintenance work is carried out, disconnect the cooker hood from the mains supply. ^ Remove the grease filter. ^ Remove the charcoal filters if the cooker hood is being used in recirculation mode.
For information on the appliance under guarantee, please contact: guarantee specific to your country – Your Miele Dealer / Chartered Agent please contact Miele. See back cover for contact details. In the U.K. your appliance is –...
– 650 mm above gas hobs and cookers If this cooker hood is installed above a Miele Wok CS 1028 CombiSet appliance, a minimum safety distance of 760 mm must be maintained between the burner and the lower edge of the cooker hood.
Installation ^ See "Connection for air extraction" for Preparation for extraction further instructions on fitting the ducting. ^ DA 2210: The hood has two exhaust connections for use with two 150 mm diameter exhaust hoses. A Y- adapter is supplied with the hood.
Page 30
(available from your Miele dealer or the Miele Spare Parts Dept.) is required. One conversion kit is required for the DA 2250 and 2270, and two kits for the DA 2210. You will also require two charcoal filters for the DA 2250 and 2270, or 4 charcoal filters for the DA 2210 (see "Technical data").
Page 31
SW 9 spanner. Do not turn the spanner. Joystick extension The joystick can be extended if required (special accessory - Miele DBV 100). 1. Screw the spring into the holder and tighten by hand. Whilst doing so counterhold the joystick with an SW 9 spanner.
Installation Electrical connection ^ If the cooker hood is to be connected to an external motor (EXT models): Use the connection cable with 6 pole plug to connect the cooker hood and the external motor. ^ Connect the appliance to the mains via a fused spur or fused socket as appropriate.
Connection for air extraction – Only use smooth pipes or flexible Important: To avoid the danger of hoses made from non-flammable toxic fumes, please observe the materials for the extraction ducting. Warning and Safety instructions. – When using an external motor, make This is especially crucial when using sure that the exhaust ducting is the cooker hood at the same time as...
Connection for air extraction Condensate trap – If the exhaust air is to be ducted into the open air, the installation of a (optional accessory) telescopic wall vent or roof vent (available as an optional accessory) is recommended. – If the exhaust air is to be ducted into a vent flue, the ducting must be directed in the flow direction of the flue.
Connection for air extraction Silencer ...with air extraction: (optional accessory) The silencer not only reduces noise from the fan, but also sounds from outside (e.g. traffic noise). For this reason the silencer must be positioned as close as possible to where the ducting leaves the building ...in recirculation mode: The silencer needs to be positioned...
Electrical connection If the switch is not accessible after All electrical work should be installation (depending on country), an undertaken by a suitably qualified additional means of disconnection must and competent person in strict be provided for all poles. accordance with current national For extra safety it is advisable to protect and local safety regulations the appliance with a suitable residual...
Operation with Control module DSM 400 The Miele DSM 400 control module can Components used in the central be used to combine the cooker hood ducting system are not supplied by with other components. Miele. It enables the following: If in any doubt, the advice of a...