hit counter code
Download Print this page

Advertisement

Quick Links

Operating and Installation
Instructions
Ventilation Hood
To prevent accidents and damage to the appliance, you must read
these instructions before installing the appliance and using it for the
first time.
en-US
M.-Nr. 12 407 020

Advertisement

loading

Summary of Contents for Miele DA1280CSS

  • Page 1 Operating and Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr. 12 407 020...
  • Page 2 Contents IMPORTANT SAFETY INSTRUCTIONS ............Caring for the environment ................12 Description of functions ................... 13 Guide to the appliance ..................14 Operation......................16 Turning the blower on and off ................16 Turning off the blower..................16 Turning the overhead lighting on/off..............16 Energy-saving tips.....................
  • Page 3 Contents Location of the data plate ................... 39 Appliance warranty and product registration ............39 Technical data ....................40...
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user.
  • Page 5  Unauthorized installation, maintenance, and repairs can cause considerable danger for the user. Installation, maintenance, and repairs must only be carried out by a Miele authorized technician.  A damaged ventilation hood can be dangerous. Always check for visible signs of damage. Never use a damaged ventilation hood.
  • Page 6 The function and operation of the protective measures provided in the domestic electrical installation and in this Miele product must also be maintained in isolated operation or in operation that is not synchronized with the grid power supply, or these measures must be replaced by equivalent measures in the installation.
  • Page 7 IMPORTANT SAFETY INSTRUCTIONS  Only open the housing as described in the enclosed “Installation diagram” and in the “Cleaning and care” section of this manual. Under no circumstances should any other parts of the housing be opened. Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operation faults.
  • Page 8 IMPORTANT SAFETY INSTRUCTIONS  Open flames are a fire hazard. The use of an open flame under the ventilation hood is not permitted. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the ventilation hood could draw flames into the filter.
  • Page 9 IMPORTANT SAFETY INSTRUCTIONS  Always turn the ventilation hood on whenever a burner is in use to prevent damage from condensation.  Overheated oil and fat can ignite, causing fire damage to the ventilation hood. Do not leave cookware, pans, and deep-fat fryers unattended when cooking with oil or fat.
  • Page 10 IMPORTANT SAFETY INSTRUCTIONS Proper installation  WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: - a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • Page 11 The steam can reach the electrical components and cause a short circuit. Accessories and parts  Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty may become void.  Defective components should be replaced by Miele original parts only.
  • Page 12 Consult with local authorities, dealers or Miele in order to dispose of and recycle electrical and electronic appliances. Miele assumes no responsibility for deleting any personal data left on the appliance being disposed.
  • Page 13 Description of functions The following functions are available on your ventilation hood, depending on the model: Extraction mode The air is drawn in and cleaned by the grease filters and directed outside. Recirculation mode The recirculation mode requires a recirculation kit and OdorFree Charcoal Filter (available as optional accessories, see “Technical Data”...
  • Page 14 Guide to the appliance...
  • Page 15 Guide to the appliance a Controls b Overhead lighting c Charcoal filters Optional accessories for recirculation mode d Cover for the charcoal filter compartment e Grease filter f Vent collar ( 6" (150 mm) or  5" (125 mm) with reducing collar). g Exhaust outlet h Recirculation vents i Sliding switch for the cooktop lighting j Sliding switch for the blower...
  • Page 16 Operation Turning the blower on and off Turning the overhead lighting on/off Turn on the blower as soon as you start cooking. This is to ensure that vapors The overhead lighting can be turned on are captured right from the start. and off independently from the blower.
  • Page 17 Energy-saving tips This hood operates in a very efficient and energy-saving manner. The following will help you to save even more energy when using it: - Ensure that there is sufficient ventilation in the kitchen when cooking. If there is insufficient air flow during extraction mode, the hood cannot operate efficiently, causing increased operating noise levels.
  • Page 18 Unsuitable cleaning agents can treating them with a stainless steel care damage the surfaces and control product (available from Miele). elements. Do not use any cleaning agents Important information for appliances containing soda, acid, chloride, or with lacquered housing solvent.
  • Page 19 Cleaning and care Important information for the Cleaning intervals controls Accumulated grease solidifies over a longer period of time and makes If soiling is not removed promptly, it cleaning more difficult. The grease could cause the control elements to filters should therefore be cleaned every alter or discolor.
  • Page 20  Use a commonly available household Regular usage and cleaning can cause dishwashing detergent. the filter surfaces to become worn.  In a Miele dishwasher use the If you identify any damage, replace the “Normal” program. grease filters. Depending on the detergent used,...
  • Page 21 The charcoal filter is installed in the canopy above the grease filters. Charcoal filters are available to order via the Miele Web Store, Miele Technical Service (see end of this manual for contact details), or from your Miele dealer. The model designations are listed in the “Technical data”...
  • Page 22 The bulbs should be replaced with the following: Bulb type ......LED, GU10 Power ..........3W Replacement bulbs are available from Miele.  Loosen the lamp's securing screw a little.  Turn off the blower and the lighting.  Slide the screw and the lamp ...
  • Page 23 *INSTALLATION* Installation Before installation  Before installation, it is important to read the information contained in this chapter and in the “IMPORTANT SAFETY INSTRUCTIONS” chapter.
  • Page 24 *INSTALLATION* Installation Installation parts...
  • Page 25 *INSTALLATION* Installation a 1 Vent collar for an exhaust duct  6“ (150 mm) or   5” (125 mm) (not to be used 4 Screws, 5 x 60 mm and with recirculation mode). 4 Wall anchors, 8 x 50 mm b 1 Non-return flap for attaching to the wall. for fitting into the exhaust socket (not to be used with recirculation ...
  • Page 26 *INSTALLATION* Installation Appliance dimensions...
  • Page 27 Please also observe the information contained in the “IMPORTANT SAFETY INSTRUCTIONS” section. Minimum distance S Cooking appliance Miele Non-Miele appliance appliance Electric Cooktops 24" (610 mm) Electric Barbeques and Fryers 26"...
  • Page 28 *INSTALLATION* Installation Installation recommendations Removing the protective film - To achieve optimum vapor extraction, Protective film has been used to cover the hood must be centered over the all housing components attached to cooktop, not to the side. stainless steel models. This will shield them from any damage that may occur - The cooktop should be no wider than during transport.
  • Page 29 *INSTALLATION* Installation  Check the installation position of the  Remove the deflector if necessary deflector. and turn it as appropriate for the operating mode required. To do this, press the two hooks, remove the deflector, turn it, and push it back in until it clicks into position.
  • Page 30 *INSTALLATION* Installation Attachment from the top Installation underneath the wall unit  Use only the attachment points shown on the drilling template and the screws supplied. Incorrect attachment can lead to damage to the hood and could compromise electrical safety (e.g. electric shock).
  • Page 31 *INSTALLATION* Installation Attachment from below As described previously, Miele recommends the attachment from above. Should it not be possible to proceed with the attachment from above, the hood can also be mounted to the cabinet's floor from below. The provided screws are intended for...
  • Page 32 *INSTALLATION* Installation Wall installation You also have the option of mounting the range hood to the wall by means of two brackets. Two mounting brackets are supplied for this purpose.  Remove the guide plugs from the housing.  Attach the pre-cut drilling template to the wall.
  • Page 33 *INSTALLATION* Installation  Attach the mounting brackets to the wall, using the wall anchors and screws provided.  The screws and plugs are designed for use in solid walls only. Use different fasteners for other wall  Removing the bulb: construction types.
  • Page 34 *INSTALLATION* Installation Preparation for vented mode  Insert the hood.  When using  6“ (150 mm) exhaust ducting, use a sharp knife to cut the exhaust socket to size with. When using  5” (125 mm) exhaust ducting, install the exhaust socket as  Insert the non-return flap, if required. ...
  • Page 35 *INSTALLATION* Installation Functional check  To do this, switch the blower on. - In extraction mode, the air should not come out of the recirculation grille at the front of the hood. - In recirculation mode, the air should come out of the recirculation grille at the front of the hood.
  • Page 36 CSA C22.1-12, appliance to your power supply, Canadian Electrical Code, Part I. please consult a licensed electrician or call Miele’s Technical Service Department. WARNING: THIS APPLIANCE MUST BE GROUNDED...
  • Page 37 “Appliance dimensions”). This applies in particular when using flat ducting. If the exhaust is ducted through an outside wall, a Miele wall vent or roof - The ducting should be as short and vent (available as an optional straight as possible.
  • Page 38 If the ducting is to run through cool the direction of airflow. rooms or ceiling space, for example, the significant variations in temperature Miele will not accept warranty claims between the different areas can cause for any functional defects or damage condensate to form. Insulate the caused by inadequate ducting.
  • Page 39 In the event of a fault which you cannot remedy yourself, please contact your Miele dealer or Miele Customer Service. You can book a Miele Service Call online at www.miele.com/service. Contact information for Miele Customer Service can be found at the end of this document.
  • Page 40 Technical data Blower motor 2 x 140 W Overhead lighting 2 x 3 W Total connected load 286 W Supply voltage, frequency 120 V AC, 60 Hz Fuse rating 15 A Power cord length 2.5 ft (0.75 m) Weight DA 1260 24.6 lbs (11.2 kg) DA 1280 30.8 lbs (14 kg) Optional accessories for recirculation mode 1 OdorFree Charcoal Filter DKF 18-900...
  • Page 43 Customer Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Headquarters and Miele Centre Princeton, NJ 08540 161 Four Valley Drive www.mieleusa.com Vaughan, ON L4K 4V8 www.miele.ca Customer Support Phone: 888-99-MIELE (64353) Customer Care Centre info@mieleusa.com...
  • Page 44 DA 1260, DA 1280 en-US M.-Nr. 12 407 020 / 00...

This manual is also suitable for:

Da 1280Da 1260Da1260ss