Operating instructions Cooker Hoods DA 196, DA 199 Q\@ä It is essential to read these Operating Instructions before installing or using the machine, to avoid the risk of accident, or damage to the machine. M.-Nr. 04 927 050...
Caring for the environment Caring for the environment Disposal of packing material Disposal of your old appliance The transport and protective packing Old appliances contain materials which has been selected from materials can be reclaimed or recycled. Please which are environmentally friendly for contact your dealer, your waste collec- disposal and can normally be recycled.
Warning and Safety instructions Warning and Safety instructions system which complies with local and This appliance meets statutory national regulations. It is most import- safety requirements. Inappropriate ant that this basic safety requirement is use could however lead to risk of ac- tested by a qualified electrician.
Page 5
Warning and Safety instructions The appliance is only completely Use of the appliance isolated from the electricity supply Never use an open flame beneath when, depending on the type of installa- the cooker hood - to avoid the tion, danger of fire do not flambé or grill –...
Page 6
These can be obtained from the cooker hood must measure at least: Miele Spare Parts department or from builders’ merchants. – 45 cm above electric hobs The appliance must not be con- –...
Page 7
Warning and Safety instructions When using the cooker hood in ex- Disposal of an old machine traction mode at the same time as or appliance another heating appliance which de- Before discarding an old machine pends on the air in the room, (e.g. gas, or appliance render it useless.
Descripton of the functions Descripton of the functions The cooker hood works with . . . Air extraction: The air is drawn in and cleaned by the grease filters and directed outside. The cooker hood is fitted with a non-return flap. This flap is closed when the cooker hood is switched off.
Guide to the appliance Guide to the appliance Extension piece Grease filter(s) Shaft Sliding switch for hob lighting Vapour guide/ canopy Sliding switch for the fan Sliding switches Sliding switch for the power setting Recirculation grille Lighting for hob...
Operation Operation After cooking Notes on the switches If the air still needs to be cleared after The sliding switch turns the hob light- cooking, we recommend letting the ing on and off. cooker hood continue to run for a fur- The sliding switch turns the fan on ther ten minutes.
Cleaning and Care Cleaning and Care Grease filters Before any cleaning or maintenance work the cooker hood must be dis- Re-usable metal grease filters are fitted connected from the mains supply. which remove solid particles (oil, dust, Depending on type of installation etc.) from the kitchen vapours, prevent- either: ing soiling of the cooker hood.
Cleaning and Care Clean the filter(s) Active charcoal filters – by hand: with a scrubbing brush in If the cooker hood is connected for re- hot water with washing-up liquid. circulation, an active charcoal filter must be inserted in addition to the –...
Cleaning and Care Changing the light tube and / or starter If the lighting is not working the light tube and/or starter may need changing. Disconnect the cooker hood from the mains supply by – switching it off at the wall socket and removing the plug (do not pull on the cable, only on the plug), or –...
After sales service After sales service In the event of any faults which you can- not easily remedy, please contact: – Your Dealer – Your nearest Service Dept, (see address on the back page). When contacting the Service Depart- ment, please quote the Model and Ser- ial number of your machine / appliance, both of which are given on the data plate which is visible on removing the...
Electrical connection and Technical data Electrical connection and Technical data Important Electrical connection The wires in the mains lead are col- General notes oured in accordance with the following code: All electrical work should only be under- taken by a suitably competent person Green/yellow = earth in strict accordance with national and...
Refer to the section on in- stallation. DA 196: B = 599 mm DA 199: B = 899 mm H = 820 - 1110 mm - recirculation mode H = 800 - 1020 mm - extraction mode...
Installation Installation Position for the extraction cut- Safety regulations prohibit the fitting out and electrical socket of this cooker hood over a solid fuel stove. The minimum safe distance S be- tween the top of the hob and the bottom of the cooker hood should be at least: –...
There are three retaining plates A, B Holes for the vapour guide (canopy). and C for fixing the cooker hood to the DA 196 wall. Drill a 6 mm diameter hole on the Before mounting the retaining plate...
Page 20
Installation Lightly screw on the retaining plate A centre horizontally to the middle line. with 5 x 40mm screws through the Mark the 4 drill holes on the wall. two holes and use the notches to With a 6 mm Ø bit drill the 4 holes in align on the middle line.
Hang the vapour guide (canopy) on to the angle brackets of retaining plate A. DA 196 Secure the vapour guide with a 4 x 30 mm screw and a 4.3 mm washer. DA 199 Secure the vapour guide with two 4 x 30 mm screws and two 4.3 mm...
Installation Motor unit Electrical Connection First push the two 4 pole plugs together. Pass the connection cable up to the First loosely screw the two self tap- left of the motor and through the ping nuts on the threaded bolts of re- cable guide.
Condensate traps are available from the Miele Spare Parts Department. When installing a condensate trap ensure that it is located vertically and if possible directly above the exhaust connection.
They are then covered by the tower shaft. Secure the flexible hose with the hose clips to the directional unit and to the exhaust socket of the motor unit. Active charcoal filters are available from the Miele Spare Parts Depart- ment or some Miele dealers.
Page 25
Installation Recirculation Extraction Pull the extension piece slightly out- wards and push over the upper re- taining plate. For recirculation make sure that the Bend the top hanging retainers ap- openings in the extension piece are po- prox. 45° inwards. This makes fitting sitioned at the same height as the air easier.
Installation Installation Fitting the tower Only for recirculation Fit the recirculation grilles into the ex- tension piece and into the directional unit behind so that the slats point downwards. Hold the main shaft gently apart and fit it over the extension piece. Then push the shaft downwards ap- prox.
Connection for air extraction Connection for air extraction – If the exhaust air is to be ducted into Danger of toxic fumes. a vent flue the ducting must be di- Please heed the “Warning and rected in the flow direction of the flue. Safety instructions”...
Page 28
Alteration rights reserved / 001 GB/IRL/AUS/NZ - 0998 This paper consists of cellulose which has been bleached without the use of chlorine.