Page 1
Operating and installation instructions Cooker hood To prevent the risk of accidents or damage to the appliance, it is es- sential to read these instructions before it is installed and used for the first time. en-GB M.-Nr. 12 406 930...
Contents Warning and Safety instructions..............Caring for the environment ................12 Modes of operation ................... 13 Guide to the cooker hood ................. 14 Operation......................16 Switching the fan on and off ................16 Run-on time......................16 Switching the fan off ................... 16 Switching the hob lighting on/off ................
Miele cannot be held liable for injury or damage caused by non- compliance with these instructions. Keep these instructions in a safe place and pass them on to any future owner.
Page 4
Warning and Safety instructions The cooker hood can only be used by people with reduced phys- ical, sensory or mental capabilities, or lack of experience and know- ledge, if they are supervised whilst using it, or have been shown how to use it in a safe way and recognise and understand the con- sequences of incorrect operation.
Page 5
Unauthorised installation, maintenance and repairs can cause considerable danger for the user. Installation, maintenance and re- pairs must only be carried out by a Miele authorised technician. A damaged appliance can be dangerous. Check it for visible signs of damage.
Page 6
Miele authorised technician to protect the user from danger. The lamps are a built-in component of the lighting. Replacement lamps may only be fitted by a Miele authorised technician or by the Miele Customer Service Department. ...
Page 7
Warning and Safety instructions Using at the same time as another heating appliance that depends on the air from the room Danger of toxic fumes! Great care should be taken when using the cooker hood in the same room or the same area of the house at the same time as an- other heating appliance that depends on the air from the room.
Page 8
Warning and Safety instructions In order to ensure safe operation and to prevent gases given off by the heating appliance from being drawn back into the room, when the cooker hood and the heater are both operated simultaneously, an underpressure in the room of 0.04 mbar (4 Pa) is the maximum permissible.
Page 9
Warning and Safety instructions Correct use Open flames are a fire hazard. The use of an open flame under the cooker hood is not permitted. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the cooker hood could draw flames into the filter.
Page 10
Wear gloves to protect your hands from being cut. Exhaust ducting must be of non-inflammable material. Suitable material is available from Miele specialist dealers or the Miele Spares Dept. The appliance must not be connected to a chimney or flue which is in use.
Page 11
Miele cannot accept liabil- ity. Miele can only guarantee the safety of the appliance when genu- ine original Miele replacement parts are used. Faulty components must only be replaced by Miele spare parts.
Miele, free of charge. By law, you are solely responsible for deleting any personal data from the old appliance prior to disposal. You are legally obliged...
Modes of operation Depending on the model of the cooker Recirculation mode hood, the following options are avail- (recirculation mode cooker hoods re- able: quire a conversion kit and charcoal fil- ter, see “Technical Data”) Extraction mode The air is drawn in and cleaned first by The air is drawn in and cleaned by the the grease filters and then by a charcoal grease filters and directed outside.
Page 15
Guide to the cooker hood a Telescopic extension piece b Tower c Canopy d Control elements e Hob lighting f Grease filters g Recirculation grille Only for recirculation mode h Charcoal filter Optional accessories for recirculation mode i Control for switching the fan off j Controls for switching the fan on and setting the fan power level k Control for switching the lighting on and off...
Operation Switching the fan on and off Switching the hob lighting on/ Switch the fan on as soon as you start cooking. This is to ensure that vapours The hob lighting can be switched on are captured right from the start. and off independently of the fan.
Energy saving tips This cooker hood operates very effi- ciently and economically. The following will help you to save even more energy when using it: - Ensure that there is sufficient ventila- tion in the kitchen when cooking. In extraction mode, if there is insuffi- cient air flow the cooker hood cannot operate efficiently and this causes in- creased operating noise levels.
Cleaning and care Important information for the control Removing a grease filter elements When handling a grease filter, be If soiling is not removed promptly, it careful not to drop it. could cause the control elements to This can result in damage to the filter alter or discolour.
Page 20
Cleaning and care Refit the grease filters, making sure Unsuitable cleaning agents that the latch faces outwards. Unsuitable cleaning agents can cause damage to the surface of the filters if used regularly. Do not use: - cleaning agents containing descaling agents - powder cleaners, cream cleaners - aggressive multi-purpose cleaning...
Remove the grease filter before fitting Charcoal filters are available to order via or replacing a charcoal filter. the Miele online shop, the Miele Cus- Take the charcoal filter out of its tomer Service Department (see end of packaging.
*INSTALLATION* Installation Before installation Before installation, it is important 8 screws, 5 x 60 mm and to read the information given on the following pages as well as the 8 plugs, 8 x 50 mm “Warning and Safety instructions” at for securing to the wall the beginning of this booklet.
Page 23
*INSTALLATION* Installation Installation kit for recirculation mode The installation kit contains deflectors with a holding plate, hose and hose clips, and a charcoal filter with installa- tion frame (not supplied, but available as an optional accessory, see “Tech- nical data”).
*INSTALLATION* Installation a Extraction b Recirculation c Ventilation grille positioned at the top for recirculation de (Only d is required for recirculation mode cooker hoods). The shaded area represents the wall or ceiling area for the ducting cut-out and for the connec- tion socket.
*INSTALLATION* Installation Installation recommendations Drilling diagram for wall mounting - When deciding on the safety distance between the hob and cooker hood, Please follow the directions given in please note that a distance of the installation instructions supplied 650 mm above electric cookers/hobs for drilling.
If the exhaust is ducted through an out- - The exhaust ducting should be as side wall, a Miele wall vent or roof vent short and straight as possible. (available as an optional accessory) is recommended.
If the exhaust ducting is to run through direction of airflow. cool rooms or ceiling space, for ex- ample, the significant variations in tem- Miele shall not accept warranty claims perature between the different areas for any functional defects or damage can cause condensation to form. Insu-...
If the mains connection cable is dam- aged, it must only be replaced with a specific mains connection cable of the same type (available from the Miele Customer Service Department). For safety reasons, such replacement may only be carried out by a qualified spe- cialist or the Miele Customer Service Department.
Page 30
The function and operation of the pro- tective measures provided in the do- mestic electrical installation and in this Miele product must also be maintained in isolated operation or in operation that is not synchronised with the mains power supply, or these measures must be replaced by equivalent measures in the installation.
Contact in the event of a fault In the event of any faults which you cannot remedy yourself, please contact your Miele dealer or the Miele Customer Service Department. You can book a Miele Customer Ser- vice Department call-out online at www.miele.com/service.
Technical data Fan motor 245 W Hob lighting 3.2 W Total rated load 248.2 W Mains voltage, frequency AC 230 V, 50 Hz Fuse rating 10 A Length of mains connection cable 1.5 m Weight DAW 1620 13.5 kg DAW 1920 15.0 kg Optional accessories for recirculation mode For recirculation mode, you need installation kit DKFS 36-P. The installation kit contains the required original equipment components and 1 charcoal filter.
Page 33
Technical data Data sheet for household cooker hoods In acc. with delegated regulation (EU) No. 65/2014 and regulation (EU) No. 66/2014 MIELE Model name/identifier DAW 1620 Active Annual Energy Consumption (AEC 49,9 kWh/year hood Energy efficiency class Energy efficiency index (EEI...
Page 34
Technical data Data sheet for household cooker hoods In acc. with delegated regulation (EU) No. 65/2014 and regulation (EU) No. 66/2014 MIELE Model name/identifier DAW 1920 Active Annual Energy Consumption (AEC 49,8 kWh/year hood Energy efficiency class Energy efficiency index (EEI...