a Suction side
b Motor can be rotated. Exhaust socket can be fitted at the top or the sides in
any direction.
c The motor unit can be freely positioned. Connection to the appliance is via the
exhaust ducting and the connection cable. Connection cable length: max.
1800 mm.
d If the cooker hood is being installed near to a wall, a minimum distance of at
least 50 mm must be observed so that the edge extraction panels and the
grease filters can be removed easily.
e The cooker hood is fastened in the cut-out using clamps. A solid ceiling
installation surface, e.g. one made of wood, is required. Make sure that the
structure can support the load. Around the clamps, components such as
supports and ducting must be at least 40 mm from the cut-out.
DA 2906 EXT/EXTA – Different appliance dimensions
Installation
35