Operation
During a programme, you can switch
between the following displays:
– the current temperature,
– the elapsed programme duration and
– the current block:
1 = Pre-wash 1
2 = Pre-wash 2
3 = Main wash 1
4 = Main wash 2
5 = Chemical disinfection*
6 = Rinse 1
7 = Rinse 2
8 = Rinse 3
9 = Rinse 4
10 = Final rinse 1
11 = Final rinse 2
13 = Drying
^ Press ß to switch between the
displays.
Programme sequence
indicators
The indicator light for the current
programme stage lights up during the
programme:
– Recharging
– Pre-wash 1 + 2
– Wash 1 + 2*
– Rinses 1 - 4 / Final rinse 1 + 2
– Dry
– Complete
End of programme
(Programme
parameters have
been reached)
36
* Wash block 5 (normally for chemical
disinfection) can be programmed in as
an additional programme stage in freely
programmable Programmes "Custom",
"Inorganica" and "Organica". It is then
not possible to dispense chemical
disinfection agents.
The programme sequence indicator
"Wash" will light up when Wash block 5
is active.
At the end of a programme
The programme has ended when
Complete lights up constantly in the
programme sequence display and the
6 indicator has gone out. An 0 will
appear in the middle of the display. All
the other indicators come on and go
out in sequence.
At the same time a buzzer sounds for a
maximum of 30 seconds (default
setting).
The buzzer can be changed; see
"Programmable functions".
Use the ß button to call up the total
running time of a programme or the
current temperature.
Immediately the programme finishes,
partially open the door of the machine
(by about 10 cm) for 10 to 15 mins.
Only then unload the machine. A good
drying result is achieved in the residual
heat, which should help to prevent the
laboratory utensils corroding.