Air extraction
Gas cooking appliances release
carbon monoxide that can be harm-
ful or fatal if inhaled. The exhaust
gases extracted by the hood
should be vented outside of the
building
Do not terminate the exhaust ducts
in attics, garages, crawlspaces, etc.
Please read and follow the
risk of personal injury, and follow all local
building codes when installing the hood.
– The ducting should be as short and
straight as possible, and the number
of sharp bends should be minimized.
– For most efficient air extraction, the
diameter of the ductwork should not
be less than 6" (150 mm). Use of flat
ducts also reduces the air extraction
efficiency.
– Noise levels of the hood will increase
if flat ducts or round ducts of less
than 6" (150 mm) in diameter are
used.
– Use smooth or flexible pipes made
– Where the ductwork is horizontal, it
– If the exhaust is ducted through an
to reduce the
– If the exhaust is ducted into an inac-
from approved non-flammable ma-
terials for exhaust ducting.
must slope away from the hood at
least 1/8" per foot (1cm per meter) to
prevent condensation dripping into
the appliance.
outside wall, a Miele Telescopic Wall
Vent can be used.
tive flue, the air must be expelled
parallel to the flow direction of the
flue.
37