Sign In
Upload
Manuals
Brands
ABB Manuals
Relays
REB650
ABB REB650 Manuals
Manuals and User Guides for ABB REB650. We have
11
ABB REB650 manuals available for free PDF download: Technical Manual, Applications Manual, Commissioning Manual, Manual, Product Manual, Operation Manual
ABB REB650 Technical Manual (436 pages)
Busbar protection
Brand:
ABB
| Category:
Protection Device
| Size: 15.16 MB
Table of Contents
Table of Contents
7
Introduction
27
This Manual
27
Intended Audience
27
Product Documentation
28
Product Documentation Set
28
Document Revision History
29
Related Documents
29
Symbols and Conventions
30
Safety Indication Symbols
30
Manual Conventions
30
Available Functions
33
Main Protection Functions
33
Back-Up Protection Functions
33
Control and Monitoring Functions
34
Designed to Communicate
36
Basic IED Functions
36
Analog Inputs
39
Introduction
39
Operation Principle
39
Settings
40
Local Human-Machine-Interface LHMI
43
Local HMI Screen Behaviour
43
Identification
43
Settings
43
Local HMI Signals
43
Function Block
44
Signals
44
Basic Part for LED Indication Module
44
Identification
44
Function Block
45
Signals
45
Settings
46
LCD Part for HMI Function Keys Control Module
46
Identification
46
Function Block
46
Signals
47
Settings
47
Operation Principle
48
Local HMI
48
Display
48
Leds
51
Keypad
51
Led
54
Functionality
54
Status Leds
54
Indication Leds
54
Function Keys
61
Functionality
61
Operation Principle
61
Differential Protection
65
1Ph High Impedance Differential Protection HZPDIF (87)
65
Identification
65
Introduction
65
Function Block
65
Signals
65
Settings
66
Monitored Data
66
Operation Principle
66
Logic Diagram
66
Technical Data
67
Current Protection
69
Four Step Phase Overcurrent Protection OC4PTOC (51/67)
69
Identification
69
Functionality
69
Function Block
69
Signals
70
Settings
71
Monitored Data
73
Operation Principle
73
Technical Data
76
Four Step Residual Overcurrent Protection EF4PTOC (51N/67N)
76
Identification
76
Functionality
76
Function Block
77
Signals
77
Settings
78
Monitored Data
81
Operation Principle
81
Operating Quantity Within the Function
81
Internal Polarizing
82
External Polarizing for Ground-Fault Function
84
Base Quantities Within the Protection
84
Internal Ground-Fault Protection Structure
84
Four Residual Overcurrent Steps
84
Directional Supervision Element with Integrated Directional Comparison Function
85
Technical Data
87
Thermal Overload Protection, Two Time Constants TRPTTR (49)
88
Identification
88
Functionality
88
Function Block
89
Signals
89
Settings
90
Monitored Data
91
Operation Principle
91
Technical Data
95
Breaker Failure Protection CCRBRF (50BF)
95
Identification
95
Functionality
95
Function Block
96
Signals
96
Settings
97
Monitored Data
97
Operation Principle
98
Technical Data
99
Pole Discrepancy Protection CCRPLD (52PD)
99
Identification
99
Functionality
99
Function Block
100
Signals
100
Settings
100
Monitored Data
101
Operation Principle
101
Pole Discrepancy Signaling from Circuit Breaker
102
Unsymmetrical Current Detection
103
Technical Data
103
Negative Sequence Based Overcurrent Function DNSPTOC (46)
103
Identification
103
Functionality
104
Function Block
104
Signals
104
Settings
105
Monitored Data
106
Operation Principle
106
Technical Data
107
Voltage Protection
109
Two Step Undervoltage Protection UV2PTUV (27)
109
Identification
109
Functionality
109
Function Block
109
Signals
110
Settings
110
Monitored Data
111
Operation Principle
111
Measurement Principle
112
Time Delay
112
Blocking
113
Design
113
Technical Data
114
Two Step Overvoltage Protection OV2PTOV (59)
115
Identification
115
Functionality
115
Function Block
115
Signals
116
Settings
116
Monitored Data
117
Operation Principle
117
Measurement Principle
118
Time Delay
118
Blocking
119
Design
120
Technical Data
121
Two Step Residual Overvoltage Protection ROV2PTOV (59N)
122
Identification
122
Functionality
122
Function Block
122
Signals
123
Settings
123
Monitored Data
124
Operation Principle
124
Measurement Principle
124
Time Delay
125
Blocking
125
Design
126
Technical Data
127
Secondary System Supervision
129
Fuse Failure Supervision SDDRFUF
129
Identification
129
Functionality
129
Function Block
129
Signals
130
Settings
130
Monitored Data
131
Operation Principle
131
Zero and Negative Sequence Detection
131
Delta Current and Delta Voltage Detection
132
Dead Line Detection
135
Main Logic
135
Technical Data
138
Breaker Close/Trip Circuit Monitoring TCSSCBR
138
Identification
138
Functionality
138
Function Block
138
Signals
139
Settings
139
Operation Principle
139
Technical Data
140
Control
141
Apparatus Control
141
Functionality
141
Bay Control QCBAY
141
Identification
141
Function Block
141
Signals
142
Settings
142
Local Remote LOCREM
142
Identification
142
Functionality
142
Function Block
143
Signals
143
Settings
143
Local Remote Control LOCREMCTRL
144
Identification
144
Functionality
144
Function Block
144
Signals
144
Settings
145
Operation Principle
145
Bay Control QCBAY
145
Local Remote/Local Remote Control LOCREM/LOCREMCTRL
147
Logic Rotating Switch for Function Selection and LHMI Presentation SLGGIO
147
Identification
147
Functionality
148
Function Block
148
Signals
148
Settings
150
Monitored Data
150
Operation Principle
150
Selector Mini Switch VSGGIO
151
Identification
151
Functionality
151
Function Block
151
Signals
151
Settings
152
Operation Principle
152
IEC 61850 Generic Communication I/O Functions DPGGIO
153
Identification
153
Functionality
153
Function Block
153
Signals
153
Settings
154
Operation Principle
154
Single Point Generic Control 8 Signals SPC8GGIO
154
Identification
154
Functionality
154
Function Block
155
Signals
155
Settings
155
Operation Principle
156
Automation Bits AUTOBITS
156
Identification
156
Functionality
157
Function Block
157
Signals
157
Settings
159
Operation Principle
159
Function Commands for IEC 60870-5-103 I103CMD
159
Functionality
159
Function Block
159
Signals
160
Settings
160
IED Commands for IEC 60870-5-103 I103IEDCMD
160
Functionality
160
Function Block
160
Signals
161
Settings
161
Function Commands User Defined for IEC 60870-5-103 I103USRCMD
161
Functionality
161
Function Block
162
Signals
162
Settings
162
Function Commands Generic for IEC 60870-5-103 I103GENCMD
163
Functionality
163
Function Block
163
Signals
163
Settings
164
IED Commands with Position and Select for IEC 60870-5-103 I103POSCMD
164
Functionality
164
Function Block
164
Signals
164
Settings
165
Logic
167
Tripping Logic SMPPTRC (94)
167
Identification
167
Functionality
167
Function Block
167
Signals
167
Settings
168
Operation Principle
168
Technical Data
169
Trip Matrix Logic TMAGGIO
169
Identification
169
Functionality
169
Function Block
170
Signals
170
Settings
171
Operation Principle
172
Configurable Logic Blocks
173
Standard Configurable Logic Blocks
173
Functionality
173
OR Function Block
174
Inverter Function Block INVERTER
175
PULSETIMER Function Block
176
Controllable Gate Function Block GATE
177
Exclusive or Function Block XOR
177
Loop Delay Function Block LOOPDELAY
178
Timer Function Block TIMERSET
179
AND Function Block
180
Set-Reset Memory Function Block SRMEMORY
181
Reset-Set with Memory Function Block RSMEMORY
182
Technical Data
184
Fixed Signals FXDSIGN
184
Identification
184
Functionality
184
Advertisement
ABB REB650 Technical Manual (504 pages)
relion 650 series Busbar protection
Brand:
ABB
| Category:
Relays
| Size: 15.46 MB
Table of Contents
Table of Contents
7
Table of Contents
14
Time Synchronization
25
Section 1 Introduction
29
This Manual
29
Intended Audience
29
Product Documentation
30
Product Documentation Set
30
Document Revision History
31
Related Documents
32
Symbols and Conventions
32
Symbols
32
Document Conventions
33
Section 2 Available Functions
35
Main Protection Functions
35
Back-Up Protection Functions
35
Control and Monitoring Functions
36
Communication
38
Basic IED Functions
39
Section 3 Analog Inputs
41
Introduction
41
Operation Principle
41
Settings
42
Section 4 Binary Input and Output Modules
47
Binary Input
47
Binary Input Debounce Filter
47
Oscillation Filter
47
Setting Parameters for Binary Input Modules
48
Settings
48
Setting Parameters for Communication Module
49
Section 5 Local Human-Machine-Interface LHMI
53
Local HMI Screen Behaviour
53
Identification
53
Settings
53
Local HMI Signals
54
Identification
54
Basic Part for LED Indication Module
55
Settings
56
LCD Part for HMI Function Keys Control Module
57
Operation Principle
58
Leds
61
Functionality
63
Function Keys
72
Ph High Impedance Differential Protection HZPDIF (87)
75
Signals
76
Logic Diagram
77
Identification
79
Function Block
80
Settings
81
Monitored Data
83
Operation Principle
84
Technical Data
88
Four Step Residual Overcurrent Protection, Zero, Negative Sequence Direction EF4PTOC (51N/67N)
89
Function Block
90
Settings
91
Monitored Data
94
Internal Polarizing
95
Operating Directional Quantity Within the Function
98
External Polarizing for Ground-Fault Function
99
Base Quantities Within the Protection
100
Directional Supervision Element with Integrated Directional Comparison Function
101
Technical Data
106
Thermal Overload Protection, Two Time Constants TRPTTR (49)
107
Signals
108
Monitored Data
109
Operation Principle
110
Technical Data
113
Function Block
114
Settings
115
Operation Principle
116
Technical Data
117
Pole Discrepancy Protection CCRPLD (52PD)
118
Function Block
119
Monitored Data
120
Pole Discrepancy Signaling from Circuit Breaker
122
Unsymmetrical Current Detection
123
Functionality
124
Settings
125
Monitored Data
126
Operation Principle
127
Two Step Undervoltage Protection UV2PTUV (27)
129
Signals
130
Monitored Data
131
Measurement Principle
132
Blocking
133
Technical Data
135
Function Block
136
Settings
137
Monitored Data
138
Measurement Principle
139
Blocking
141
Technical Data
143
Function Block
144
Settings
145
Measurement Principle
146
Blocking
147
Technical Data
149
Fuse Failure Supervision SDDRFUF
151
Function Block
152
Settings
153
Monitored Data
154
Delta Current and Delta Voltage Detection
155
Dead Line Detection
158
Technical Data
162
Function Block
163
Technical Data
164
Apparatus Control
165
Function Block
166
Local Remote LOCREM
167
Settings
168
Signals
169
Operation Principle
170
Local Remote/Local Remote Control LOCREM LOCREMCTRL
171
Logic Rotating Switch for Function Selection and LHMI Presentation SLGGIO
172
Functionality
173
Settings
175
Selector Mini Switch VSGGIO
176
Settings
177
IEC 61850 Generic Communication I/O Functions DPGGIO
178
Function Block
179
Single Point Generic Control 8 Signals SPC8GGIO
180
Settings
181
Operation Principle
182
Function Block
183
Settings
184
Operation Principle
185
Signals
186
Signals
187
Function Block
188
Function Commands Generic for IEC 60870-5-103 I103GENCMD
189
Settings
190
Settings
191
Tripping Logic Common 3-Phase Output SMPPTRC (94)
193
Signals
194
Technical Data
195
Functionality
196
Signals
197
Settings
198
Configurable Logic Blocks
200
OR Function Block
201
Inverter Function Block INVERTER
202
Controllable Gate Function Block GATE
203
Exclusive or Function Block XOR
204
Loop Delay Function Block LOOPDELAY
205
Timer Function Block TIMERSET
206
AND Function Block
207
Set-Reset Memory Function Block SRMEMORY
208
Reset-Set with Memory Function Block RSMEMORY
210
Technical Data
211
Fixed Signals FXDSIGN
212
Settings
213
Function Block
214
Settings
215
Function Block
216
Settings
217
Function Block
218
Settings
219
Function Block
220
Settings
221
Measurements
223
Measurements CVMMXN
224
Function Block
225
Settings
226
Monitored Data
229
Phase Current Measurement CMMXU
230
Settings
231
Monitored Data
232
Signals
233
Settings
234
Current Sequence Component Measurement CMSQI
235
Settings
236
Monitored Data
237
Voltage Sequence Measurement VMSQI
238
Settings
239
Monitored Data
240
Phase-Neutral Voltage Measurement VNMMXU
241
Settings
242
Monitored Data
243
Measurements CVMMXN
247
Phase Current Measurement CMMXU
252
Phase-Phase and Phase-Neutral Voltage Measurements VMMXU, VNMMXU
253
Event Counter CNTGGIO
254
Signals
255
Operation Principle
256
Disturbance Report
257
Function Block
258
Monitored Data
259
Measured Values
262
Analog Input Signals Axradr
263
Settings
264
Analog Input Signals A4RADR
268
Signals
269
Binary Input Signals Bxrbdr
273
Signals
274
Operation Principle
280
Disturbance Information
282
Time Tagging
283
Analog Signals
284
Binary Signals
285
Post Retrigger
286
Technical Data
287
Indications
288
Technical Data
289
Function Block
290
Technical Data
291
Technical Data
292
Signals
293
Disturbance Recorder
294
Memory and Storage
295
Technical Data
297
Signals
298
Function Block
299
Settings
300
Operation Principle
301
Signals
302
Monitored Data
303
Function Block
304
Fault Locator LMBRFLO
305
Function Block
306
Settings
307
Monitored Data
308
Measuring Principle
309
The Non-Compensated Impedance Model
313
Technical Data
314
Function Block
315
Settings
316
Technical Data
318
Signals
319
Settings
320
Technical Data
321
Function Block
322
SSIML Outputsignals
323
Operation Principle
324
Functionality
325
Settings
326
Monitored Data
327
Operation Principle
328
Circuit Breaker Status
329
Circuit Breaker Operation Monitoring
330
Breaker Contact Travel Time
331
Operation Counter
333
Remaining Life of the Circuit Breaker
335
Circuit Breaker Spring Charged Indication
336
Gas Pressure Supervision
337
Technical Data
338
Function Block
339
Signals
340
I103Measusr
341
Settings
342
Function Block
343
Function Block
344
Function Block
345
Settings
346
IED Status for IEC 60870-5-103 I103IED
347
Supervison Status for IEC 60870-5-103 I103SUPERV
348
Status for User Defined Signals for IEC 60870-5-103 I103USRDEF
349
Signals
350
Pulse Counter PCGGIO
351
Signals
352
Monitored Data
353
Technical Data
354
Energy Calculation and Demand Handling ETPMMTR
355
Signals
356
Settings
357
Monitored Data
358
Technical Data
359
DNP3 Protocol
361
Communication Interfaces and Protocols
362
Technical Data
363
Function Block
364
Settings
366
Function Block
367
Settings
368
GOOSE Function Block to Receive a Double Point Value GOOSEDPRCV
369
Settings
370
Functionality
371
GOOSE Function Block to Receive a Measurand Value GOOSEMVRCV
372
Signals
373
GOOSE Function Block to Receive a Single Point Value GOOSESPRCV
374
Settings
375
Settings
376
Self Supervision with Internal Event List
379
Signals
380
Internal Signals
383
Run-Time Model
384
Technical Data
385
Time Synchronization
386
Settings
387
Settings
388
Settings
389
Time Synchronization Via IRIG-B
390
Real-Time Clock (RTC) Operation
392
Synchronization Alternatives
393
Technical Data
394
Setting Group Handling SETGRPS
395
Signals
396
Test Mode Functionality TESTMODE
397
Functionality
398
Settings
399
Change Lock Function CHNGLCK
400
Function Block
401
IED Identifiers TERMINALID
402
Product Information
403
Primary System Values PRIMVAL
404
Identification
405
Signals
406
Settings
407
Operation Principle
409
Summation Block 3 Phase 3PHSUM
413
Settings
414
Identification
415
Functionality
416
Authorization Handling in the IED
417
Functionality
418
Denial of Service
419
Settings
420
Function Block
421
Operation Principle
422
Protective Ground Connections
423
Inputs
424
Binary Inputs
425
Outputs
428
Outputs for Signalling
430
Communication Connections
433
Station Communication Rear Connection
434
Communication Interfaces and Protocols
435
Connection Diagrams for 650 Series
436
Connection Diagrams for REB650 A03A
445
Section 17 Technical Data
455
Energizing Inputs
456
Signal Outputs
457
Data Communication Interfaces
458
Enclosure Class
459
Environmental Conditions and Tests
460
Section 18 IED and Functionality Tests
461
Insulation Tests
463
EMC Compliance
464
Section 19 Time Inverse Characteristics
465
Operation Principle
468
Inverse Time Characteristics
471
Section 20 Glossary
495
ABB REB650 Applications Manual (322 pages)
RELION 650 SERIES, Busbar protection
Brand:
ABB
| Category:
Power distribution unit
| Size: 9.16 MB
Table of Contents
Table of Contents
7
Section 1 Introduction
19
This Manual
19
Presumptions for Technical Data
19
Intended Audience
20
Product Documentation
20
Product Documentation Set
20
Document Revision History
22
Related Documents
22
Document Symbols and Conventions
23
Symbols
23
Document Conventions
24
IEC 61850 Edition 1 / Edition 2 Mapping
24
Section 2 Application
29
General IED Application
29
Main Protection Functions
30
Back-Up Protection Functions
30
Control and Monitoring Functions
31
Communication
34
Basic IED Functions
36
Section 3 Configuration
39
Description of Configuration REB650
39
Introduction
39
Description of A03
39
Section 4 Analog Inputs
41
Introduction
41
Setting Guidelines
41
Setting of the Phase Reference Channel
42
Example
42
Setting of Current Channels
42
Example 1
42
Example 2
43
Example 3
44
Examples on How to Connect, Configure and Set CT Inputs for most Commonly Used CT Connections
47
Example on How to Connect a Star Connected Three- Phase CT Set to the IED
48
Example How to Connect Delta Connected Three-Phase CT Set to the IED
52
Example How to Connect Single-Phase CT to the IED
55
Example
57
Relationships between Setting Parameter Base Current, CT Rated Primary Current and Minimum Pickup of a Protection IED
57
Setting of Voltage Channels
57
Examples How to Connect, Configure and Set VT Inputs for most Commonly Used VT Connections
58
Examples on How to Connect a Three Phase-To-Earth Connected VT to the IED
59
Example on How to Connect a Phase-To-Phase Connected VT to the IED
61
Example on How to Connect an Open Delta VT to the IED for High Impedance Earthed or Unearthed Networks
63
Example How to Connect the Open Delta VT to the IED for Low Impedance Earthed or Solidly Earthed Power Systems
66
Section 5 Local HMI
69
Display
70
Leds
72
Keypad
73
Local HMI Functionality
75
Protection and Alarm Indication
75
Parameter Management
76
Front Communication
77
Section 6 Differential Protection
79
High Impedance Differential Protection, Single Phase HZPDIF
79
Identification
79
Application
79
The Basics of the High Impedance Principle
80
Connection Examples for High Impedance Differential Protection
86
Connections for Three-Phase High Impedance Differential Protection
86
Connections for 1Ph High Impedance Differential Protection HZPDIF
87
Configuration
88
Setting Guidelines
88
Settings of Protection Function
88
T-Feeder Protection
89
Tertiary Reactor Protection
92
Alarm Level Operation
95
Section 7 Current Protection
97
Directional Phase Overcurrent Protection, Four Steps OC4PTOC
97
Identification
97
Application
97
Setting Guidelines
98
Settings for each Step
100
Setting Example
103
Directional Residual Overcurrent Protection, Four Steps EF4PTOC
108
Identification
108
Application
108
Setting Guidelines
110
Common Settings for All Steps
111
2Nd Harmonic Restrain
112
Parallel Transformer Inrush Current Logic
112
Switch Onto Fault Logic
113
Settings for each Step (X = 1, 2, 3 and 4)
114
Four Step Directional Negative Phase Sequence Overcurrent Protection NS4PTOC
117
Identification
117
Application
117
Setting Guidelines
119
Settings for each Step
119
Common Settings for All Steps
122
Thermal Overload Protection, Two Time Constants TRPTTR
123
Identification
124
Application
124
Setting Guideline
125
Setting Example
127
Breaker Failure Protection CCRBRF
129
Identification
129
Application
130
Setting Guidelines
130
Pole Discordance Protection CCPDSC
133
Identification
134
Application
134
Setting Guidelines
134
Section 8 Voltage Protection
137
Two Step Undervoltage Protection UV2PTUV
137
Identification
137
Application
137
Setting Guidelines
138
Backup Protection for Power System Faults
138
Disconnected Equipment Detection
138
Equipment Protection, such as for Motors and Generators
138
Power Supply Quality
138
Voltage Instability Mitigation
138
Settings for Two Step Undervoltage Protection
139
Two Step Overvoltage Protection OV2PTOV
140
Identification
140
Application
141
Setting Guidelines
141
Equipment Protection, Capacitors
142
Equipment Protection, such as for Motors, Generators, Reactors and Transformers
142
High Impedance Earthed Systems
142
Power Supply Quality
142
The Following Settings Can be Done for the Two Step Overvoltage Protection
142
Two Step Residual Overvoltage Protection ROV2PTOV
145
Application
145
Identification
145
Setting Guidelines
145
Equipment Protection, Capacitors
146
Equipment Protection, such as for Motors, Generators, Reactors and Transformersequipment Protection for Transformers
146
High Impedance Earthed Systems
146
Power Supply Quality
146
Direct Earthed System
147
Settings for Two Step Residual Overvoltage Protection
148
Section 9 Secondary System Supervision
151
Fuse Failure Supervision FUFSPVC
151
Identification
151
Application
151
Setting Guidelines
152
General
152
Setting of Common Parameters
152
Negative Sequence Based
153
Delta U and Delta I
154
Zero Sequence Based
154
Dead Line Detection
155
Advertisement
ABB REB650 Commissioning Manual (114 pages)
Busbar protection
Brand:
ABB
| Category:
Industrial Equipment
| Size: 2.66 MB
Table of Contents
Table of Contents
7
Introduction
13
This Manual
13
Intended Audience
13
Product Documentation
14
Product Documentation Set
14
Document Revision History
15
Related Documents
15
Document Symbols and Conventions
16
Symbols
16
Document Conventions
17
IEC 61850 Edition 1 / Edition 2 Mapping
17
Safety Information
21
Symbols on the Product
21
Warnings
21
Caution Signs
22
Note Signs
23
Available Functions
25
Main Protection Functions
25
Back-Up Protection Functions
25
Control and Monitoring Functions
26
Communication
29
Basic IED Functions
30
Starting up
33
Factory and Site Acceptance Testing
33
Commissioning Checklist
33
Checking the Power Supply
33
Energizing the IED
34
Checking the IED Operation
34
IED Start-Up Sequence
34
Setting up Communication between PCM600 and the IED
35
Writing an Application Configuration to the IED
39
Checking CT Circuits
39
Checking VT Circuits
40
Using the RTXP Test Switch
40
Checking the Binary Input/Output Circuits
41
Binary Input Circuits
41
Binary Output Circuits
41
Checking Optical Connections
41
Configuring the IED and Changing Settings
43
Overview
43
Configuring Analog CT Inputs
43
Supervision of Input/Output Modules
44
Establishing Connection and Verifying the SPA/IEC Communication
45
Entering Settings
45
Entering SPA Settings
45
Entering IEC Settings
45
Verifying the Communication
45
Verifying SPA Communication
46
Verifying IEC Communication
46
Fiber Optic Loop
46
Optical Budget Calculation for Serial Communication with SPA/IEC
47
Establishing Connection and Verifying the LON Communication
49
Communication Via the Rear Ports
49
LON Communication
49
The LON Protocol
50
Hardware and Software Modules
50
Optical Budget Calculation for Serial Communication with LON
51
Testing IED Operation
53
Preparing for Test
53
Requirements
53
Preparing the IED to Verify Settings
54
Activating the Test Mode
55
Preparing the Connection to the Test Equipment
55
Connecting the Test Equipment to the IED
56
Releasing the Function to be Tested
56
Verifying Analog Primary and Secondary Measurement
57
Testing the Protection Functionality
57
Forcing of Binary Input/Output Signals for Testing
58
Forcing Concept
58
How to Enable Forcing
58
Enable Forcing by Using LHMI
58
Enable Forcing Using TESTMODE Function Block
58
How to Change Binary Input/Output Signals Using Forcing
59
Forcing by Using LHMI
59
Forcing by Using PCM600
60
How to Undo Forcing Changes and Return the IED to Normal Operation
62
Undo Forcing by Using TESTMODE Component
62
Undo Forcing by Using LHMI
62
ABB REB650 Applications Manual (262 pages)
Brand:
ABB
| Category:
Industrial Equipment
| Size: 5.99 MB
Table of Contents
Table of Contents
7
Introduction
17
This Manual
17
Intended Audience
17
Product Documentation
18
Product Documentation Set
18
Document Revision History
19
Related Documents
19
Symbols and Conventions
20
Symbols
20
Document Conventions
20
Application
23
REB650 Application
23
Available Functions
24
Main Protection Functions
24
Back-Up Protection Functions
25
Control and Monitoring Functions
25
Station Communication
29
Basic IED Functions
30
REB650 Application Examples
31
Adaptation to Different Applications
31
Protection of a Two Section Busbar with Additional Bus Coupler Protection Functions
31
Protection of a Single Section Busbar
32
Functionality Table
32
REB650 Setting Examples
35
Busbar Protection Application
35
Calculating General Settings for Analogue TRM Inputs 6I 4U
37
Calculating General Settings for Analogue AIM Inputs 6I 4U
38
Preprocessing Blocks (SMAI)
39
Calculating Settings for Global Base Values for Setting Function GBASVAL
39
Calculating Settings for Busbar High Impedance Differential Protection HZPDIF (87)
39
Calculating Settings for Breaker Failure Protection 3-Phase Activation and Output CCRBRF (50BF)
41
Calculating Settings for Pole Discordance Protection CCRPLD (52PD)
42
Analog Inputs
43
Introduction
43
Setting Guidelines
43
ABB REB650 Commissioning Manual (90 pages)
Busbar protection
Brand:
ABB
| Category:
Power distribution unit
| Size: 2.99 MB
Table of Contents
Table of Contents
7
Introduction
11
Intended Audience
11
This Manual
11
Product Documentation
12
Product Documentation Set
12
Document Revision History
13
Related Documents
13
Document Conventions
14
Safety Information
17
Symbols
14
Symbols and Conventions
14
Symbols on the Product
17
Warnings
17
Caution Signs
18
Note Signs
19
Available Functions
21
Back-Up Protection Functions
21
Main Protection Functions
21
Control and Monitoring Functions
22
Station Communication
25
Basic IED Functions
26
Starting up
29
Commissioning Checklist
29
Factory and Site Acceptance Testing
29
Checking the IED Operation
30
Checking the Power Supply
30
Energizing the IED
30
IED Start-Up Sequence
30
Setting up Communication between PCM600 and the IED
31
Writing an Application Configuration to the IED
36
Checking CT Circuits
37
Checking VT Circuits
37
Using the RTXP Test Switch
38
Binary Input Circuits
39
Binary Output Circuits
39
Checking Binary Input and Output Circuits
39
Checking Optical Connections
39
Establishing Connection and Verifying the IEC 61850 Station Communication
41
Setting the Station Communication
41
Verifying the Station Communication
41
Testing IED Operation
43
Preparing the IED to Verify Settings
43
Activating the Test Mode
44
Connecting the Test Equipment to the IED
45
Preparing the Connection to the Test Equipment
45
Releasing the Function to be Tested
46
Verifying Analog Primary and Secondary Measurement
47
Testing the Protection Functionality
48
Testing Functionality
49
High Impedance Differential Protection HZPDIF (87)
49
Identifying the Function to Test in the Technical Reference Manual
49
Introduction
49
Disturbance Report Settings
49
Testing Differential Protection Functions
49
Testing Disturbance Report
49
Completing the Test
50
Four Step Phase Overcurrent Protection 3-Phase Output OC4PTOC (51_67)
50
Testing Current Protection Functions
50
Verifying the Settings
50
Completing the Test
51
Verifying the Settings
51
Completing the Test
52
Four Step Directional Residual Overcurrent Protection
52
Four Step Non-Directional Residual Overcurrent Protection
52
Four Step Residual Overcurrent Protection, Zero or Negative Sequence Direction EF4PTOC (51N/67N)
52
Checking Operate and Reset Values
53
Thermal Overload Protection, Two Time Constants TRPTTR (49)
53
Breaker Failure Protection, Phase Segregated Activation and Output CCRBRF (50BF)
54
Checking the Phase Current Operate Value, Pickup_Ph
54
Completing the Test
54
Checking the Re-Trip and Back-Up Times
55
Checking the Residual (Ground Fault) Current Operate Value Pickup_N Set below
55
Pickup_Ph
55
Verifying the Re-Trip Mode
55
Verifying the Back-Up Trip Mode
56
Verifying the Case Retripmode = Contact
57
Verifying the Function Mode Current&Contact
57
Completing the Test
58
Pole Discrepancy Protection CCRPLD (52PD)
58
Verifying the Settings
58
Testing Voltage Protection Functions
59
Two Step Undervoltage Protection UV2PTUV (27)
59
Verifying the Setting
59
Completing the Test
60
Two Step Overvoltage Protection OV2PTOV (59)
60
Verification of Single-Phase Voltage and Time Delay to Operate for Step 1
60
Completing the Test
61
Two Step Residual Overvoltage Protection ROV2PTOV (59N)
61
Completing the Test
62
Verifying the Settings
62
Checking that the Binary Inputs and Outputs Operate as Expected
63
Fuse Failure Supervision SDDRFUF
63
Testing Frequency Protection Functions
63
Testing Secondary System Supervision Functions
63
Measuring the Operate Value for the Negative Sequence Function
64
Measuring the Operate Value for the Zero-Sequence Function
64
Checking the Operation of the DV/Dt and DI/Dt Based Function
65
Circuit Breaker Lockout
66
Completing the Test
66
Testing Logic Functions
66
Testing Scheme Communication Functions
66
Three-Phase Operating Mode
66
Tripping Logic, Common 3-Phase Output SMPPTRC (94)
66
Completing the Test
67
Event Counter CNTGGIO
67
Limit Counter L4UFCNT
67
Testing Monitoring Functions
67
Establishing Connection and Verifying the IEC 61850 Communication
68
Overview
68
Pulse Counter PCGGIO
68
Setting the Station Communication
68
Testing Metering Functions
68
Testing Station Communication
68
Verifying the Station Communication
69
Exit Test Mode
70
Commissioning and Maintenance of the Fault Clearing System
71
Commissioning Tests
71
Periodic Maintenance Tests
71
Maintenance Tests
72
Troubleshooting
75
Visual Inspection
72
Checking the Communication Link Operation
75
Fault Tracing
75
Identifying Communication Errors
75
Identifying Hardware Errors
75
Identifying Runtime Errors
75
Checking the Time Synchronization
76
Indication Messages
76
Internal Faults
76
Running the Display Test
76
Warnings
77
Additional Indications
78
Changing and Setting the Password
78
Correction Procedures
78
Identifying IED Application Problems
78
Inspecting the Wiring
78
ABB REB650 Commissioning Manual (80 pages)
Busbar protection Version 1.1 IEC
Brand:
ABB
| Category:
Relays
| Size: 2.22 MB
Table of Contents
Table of Contents
7
Introduction
11
Intended Audience
11
This Manual
11
Product Documentation
12
Product Documentation Set
12
Document Revision History
13
Related Documents
13
Manual Conventions
14
Safety Information
15
Safety Indication Symbols
14
Symbols and Conventions
14
Symbols on the Product
15
Warnings
15
Caution Signs
16
Note Signs
17
Available Functions
19
Back-Up Protection Functions
19
Main Protection Functions
19
Control and Monitoring Functions
20
Basic IED Functions
22
Starting up
25
Designed to Communicate
22
Commissioning Checklist
25
Factory and Site Acceptance Testing
25
Checking the IED Operation
26
Checking the Power Supply
26
Energizing the IED
26
IED Start-Up Sequence
26
Setting up Communication between PCM600 and the IED
27
Writing an Application Configuration to the IED
30
Checking CT Circuits
31
Checking VT Circuits
31
Binary Input Circuits
32
Checking Binary Input and Output Circuits
32
Checking the RTXP Test Switch
32
Binary Output Circuits
33
Checking Optical Connections
33
Establishing Connection and Verifying the IEC 61850 Station Communication
35
Setting the Station Communication
35
Verifying the Communication
35
Testing IED Operation
37
Preparing the IED to Verify Settings
37
Activating Test Mode
38
Connecting Test Equipment to the IED
39
Preparing the Connection to the Test Equipment
39
Releasing the Function to be Tested
40
Verifying Analog Primary and Secondary Measurement
41
Testing Protection Functionality
42
Testing Functionality
43
Disturbance Report Settings
43
High Impedance Differential Protection HZPDIF
43
Identifying the Function to Test in the Technical Reference Manual
43
Introduction
43
Testing Differential Protection Functions
43
Testing Disturbance Report
43
Verifying the Settings
43
Completing the Test
44
Four Step Phase Overcurrent Protection OC4PTOC
44
Testing Current Protection Functions
44
Verifying the Settings
44
Completing the Test
45
Four Step Residual Overcurrent Protection EF4PTOC
45
Completing the Test
46
Four Step Directional Residual Overcurrent Protection
46
Four Step Non-Directional Residual Overcurrent Protection
46
Thermal Overload Protection, Two Time Constants TRPTTR
46
Checking Operate and Reset Values
47
Completing the Test
47
Breaker Failure Protection CCRBRF
48
Checking the Phase Current Operate Value, IP
48
Checking the Re-Trip and Back-Up Times
48
Checking the Residual (Earth Fault) Current Operate Value IN> Set below IP
48
Verifying the Back-Up Trip Mode
49
Verifying the Re-Trip Mode
49
Verifying the Case Retripmode = Contact
50
Verifying the Function Mode Current&Contact
50
Completing the Test
51
Pole Discordance Protection CCRPLD
51
Verifying the Settings
51
Completing the Test
52
Testing Voltage Protection Functions
52
Two Step Overvoltage Protection OV2PTOV
52
Two Step Undervoltage Protection UV2PTUV
52
Verifying the Setting
52
Completing the Test
53
Two Step Residual Overvoltage Protection ROV2PTOV
53
Verifying the Settings
53
Checking that the Binary Inputs and Outputs Operate as Expected
54
Fuse Failure Supervision SDDRFUF
54
Measuring the Operate Value for the Negative Sequence Function
54
Testing Secondary System Supervision Functions
54
Checking the Operation of the Du/Dt and DI/Dt Based Function
55
Measuring the Operate Value for the Zero-Sequence Function
55
Circuit Breaker Lockout
56
Completing the Test
56
Testing Logic Functions
56
Three Phase Operating Mode
56
Tripping Logic SMPPTRC
56
Completing the Test
57
Event Counter CNTGGIO
57
Exit Test Mode
57
Commissioning and Maintenance of the Fault Clearing System
59
Pulse Counter PCGGIO
57
Testing Metering Functions
57
Testing Monitoring Functions
57
Installation and Commissioning
59
Commissioning Tests
60
Periodic Maintenance Tests
60
Maintenance Tests
61
Troubleshooting
65
Visual Inspection
61
Checking the Communication Link Operation
65
Fault Tracing
65
Identifying Communication Errors
65
Identifying Hardware Errors
65
Identifying Runtime Errors
65
Checking the Time Synchronization
66
Indication Messages
66
Internal Faults
66
Running the Display Test
66
Additional Indications
67
Warnings
67
Changing and Setting the Password
68
Correction Procedures
68
Identifying IED Application Problems
68
Inspecting the Wiring
68
ABB REB650 Operation Manual (66 pages)
Brand:
ABB
| Category:
Protection Device
| Size: 4.52 MB
Table of Contents
Table of Contents
7
Introduction
11
This Manual
11
Intended Audience
11
Product Documentation
12
Product Documentation Set
12
Document Revision History
13
Related Documents
13
Document Symbols and Conventions
15
Symbols
15
Document Conventions
16
Safety Information
17
Symbols on the Product
17
Warnings
17
Caution Signs
18
Note Signs
19
Environmental Aspects
21
Sustainable Development
21
Disposing of the IED
21
Using the HMI
23
Using the Local HMI
23
On-Screen Keyboard
23
Logging on
24
Logging off
26
Turning the Display Backlight on
26
Identifying the Device
26
Adjusting the Display Contrast
27
Navigating in the Menu
27
Menu Structure
27
Scrolling the Display
28
Changing the Default View
28
Browsing Setting Values
28
Editing Values
29
Editing Numerical Values
29
Editing String Values
30
Editing Enumerated Values
30
Changing Time Settings in LHMI
30
Saving Settings
31
Clearing and Acknowledging
31
Using the Local HMI Help
31
IED Operation
33
Normal Operation
33
Disturbance Identification
33
Disturbance Recording Triggering
33
Disturbance Record Analysis
33
Disturbance Reports
34
IED Self-Supervision
34
Non-Operative Functions
34
IED Parameterization
35
IED Settings for IED Functionality
35
ABB REB650 Manual (96 pages)
RELION DNP, 650 series Version 2.2
Brand:
ABB
| Category:
Protection Device
| Size: 2.99 MB
Table of Contents
Table of Contents
7
Section 1 Introduction
9
This Manual
9
Intended Audience
9
Product Documentation
10
Product Documentation Set
10
Document Revision History
11
Related Documents
12
Document Symbols and Conventions
13
Symbols
13
Document Conventions
14
Section 2 DNP3 Data Mappings
17
Overview
17
Point List for the Ieds
17
BI4 Binary Input
28
Section 3 DNP3 Protocol Implementation
33
DNP3 Device Profile
33
DNP3 Implementation Table
77
Section 4 Glossary
85
Glossary
85
ABB REB650 Product Manual (73 pages)
Generator protection Relion 650 series
Brand:
ABB
| Category:
Other
| Size: 1.3 MB
Table of Contents
Table of Contents
2
Series Overview
3
Application
3
Available Functions
6
Differential Protection
13
Impedance Protection
14
Current Protection
15
Voltage Protection
17
Frequency Protection
18
Secondary System Supervision
18
Control
19
Logic
21
Monitoring
22
Metering
24
Human Machine Interface
25
Basic IED Functions
25
Station Communication
27
Hardware Description
28
Connection Diagrams
29
Technical Data
30
Ordering for Customized IED
63
Ordering for Configured IED
67
Ordering for Accessories
69
ABB REB650 Product Manual (49 pages)
Busbar protection Version 1.1 ANSI
Brand:
ABB
| Category:
Industrial Equipment
| Size: 2.8 MB
Table of Contents
Table of Contents
2
Series Overview
3
Application
3
Available Functions
5
Differential Protection
9
Current Protection
9
Voltage Protection
11
Secondary System Supervision
11
Control
12
Logic
12
Monitoring
13
Metering
15
Human Machine Interface
15
Basic IED Functions
16
Station Communication
16
Hardware Description
17
Connection Diagrams
19
Technical Data
20
Ordering
43
Advertisement
Related Products
ABB Relion REB500
ABB REM 610
ABB RET615 B
ABB RET615 F
ABB REM615 A
ABB REU615 B
ABB REA 10 Series
ABB REJ 525
ABB REJ 523
ABB RE 610 Series
ABB Categories
Industrial Equipment
Controller
Measuring Instruments
Battery Charger
DC Drives
More ABB Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL