REFRIGER ANT SYS T E M D IAG RA M Refrigerant direction : Cool : Heat INDOOR UNIT OUTDOOR UNIT Pressure Refrigerant Pipe Check Valve 15.88mm (5/8") High Pressure Charging Switch Valve 4-way Condenser Evaporator Valve Accumulator Compressor Refrigerant Pipe 9.52mm (3/8") Strainer Strainer...
C IRC UIT DIAGRA M INDOOR UNIT OUTDOOR UNIT HIGH PRESSURE SWITCH BLACK GRAY THERMISTOR CN90 BLACK GRAY ( PIPE TEMP. ) THERMISTOR ( COMPRESSOR TEMP. ) BLACK BROWN THERMISTOR BLACK CN64 ( ROOM TEMP. ) BROWN CN42 CN40 CN200 CN400 1 2 3 4 5 1 2 3 4 5 6 7 8 9...
INDO OR PC B CI RC UI T DI AGRAM INVERTER UNIT ABYA30LBT : EZ-00712HSE ROOM TEMPERATURE THERMISTOR ABYA36LBT : EZ-00713HSE CN8-1 BLACK B02B-XASK-1-A BLACK CN8-2 WHITE CN2-1 CN2-2 CN7-1 CN2-3 B02B-XAYK-1-A TEST B5P-SHF-1AA CN7-2 CN2-4 YELLOW WHITE CN2-5 PIPE TEMPERATURE THERMISTOR ( M I D )
Page 8
INDOOR UNIT CONTROLLER PCB ASSEMBLY ( MAIN PCB ) ABYA30LBT : K06AK-0708HSE-C1 ABYA36LBT : K06AK-0709HSE-C1 R1 - R3 1SS355 10K <1/10W> x 3 ROOM TEMP. TH. I C8 13.5V NJM7812 FLOAT SWITCH B2B-XASK-1-A R4 - R6 1.0K 1.0K <1/10W> x 3 <1/10W>...
O UTD OOR PCB CI RCUI T D IA GR A M INVERTER ASSEMBLY AOYA30LBTL : EZ-007LHUE AOYA36LBTL : EZ-007MHUE EMI FILTER ZCAT2132-1130 1 TURN UL1015 AWG14 WHITE POWER SOURCE EMI FILTER UL1015 UL1015 AC230V ZCAT2132-1130 AWG14 AWG14 BLACK BLACK 2 TURN 50Hz UL3271...
Page 12
OUTDOOR UNIT CONTROLLER PCB ASSEMBLY ( MAIN PCB ) AOYA30LBTL : K07BS-0704HUE-C1 AOYA36LBTL : K07BS-0705HUE-C1 CN200 DC HIGH VOLTAGE 1-1747052-2 R640 FH200 FH201 150K <1/3W> 1SS355 DC VOLT I N PFC5000 CURRENT DETECTION CIRCUIT VOLTAGE LOCK OUT CIRCUIT -0502 x 2 F201 R601 1.0K R603...
Page 13
OUTDOOR UNIT TRANSISTOR PCB ASSEMBLY K07BT-0702HUE-TR0 DB CIRCUIT PEAK LOAD CURRENT DETECTION CIRCUIT TM101 ORANGE C161 100P <CH> <X7R> TM102 BLACK BROWN D100 R44 30K <1/10W> D25XB60 CN303 1.0K R42, R43 1971032-5 <1/10W> <1/10W> WHITE 4.7K <1/10W> 1% x 2 RB751V PEAK LOAD CURRENT DETECTION REVERSE CURRENT DETECTION...
Page 14
OUTDOOR UNIT POWER SUPPLY PCB ASSEMBLY K05CW-0702HUE-FL0 CT OUT ORANGE BLACK GRAY PTC OUT ORANGE VA100, VA101 L102 C105, C104 470V <TNR> x 2 N200500K1D7C 0.033 <YE> x 2 ORANGE BLACK C100 C103 C106 C108 K101 DW12D1 <LE> <LE> <LE> <LE>...
Page 15
OUTDOOR UNIT CONDENSOR PCB ASSEMBLY K05FB-0700HUE-P0 C200 - C203 660 / 450V x 4 WHITE YELLOW R200 220K <2W> BLUE VIOLET POWER-G www.enindel.com 2007.12.19...
E R RO R CO NT E NT S INDOOR UNIT (Troubleshooting with the indoor display) Troubleshooting at the display is possible either on the wired or wireless remote control. FILTER lamp (Red) TIMER lamp (Orange) OPERATION lamp (Green) The OPERATION, TIMER and FILTER lamps operate according to the following error contents.
Page 17
TROUBLESHOOTING AT THE REMOTE CONTROL LCD You will find this on the wired remote control LCD. (option) If an error occurs, the following display will be shown. ("EE" will appear in the set room temperature display.) If "CO" appears in the unit number display, there is a remote control error. Refer to the installation instruction sheet included with the remote control.
Page 18
OUTDOOR UNIT SPECIAL INSTALLATION SETTING CAUTION Always turn on the power 12 hours prior to the start of the PUMP DOWN (Refrigerant collecting operation) operation in order to ensure compressor protection Perform the following procedures to collect the refrigerant when moving the indoor unit or the outdoor unit.
PARTS INDOOR UNIT Ref. Description Part number Kit (Base Sub Assy) 9371360010 Panel Left Sub Assy 9360427014 Kit (Panel Right Assy) 9371361017 Cover (Top) 9359737001 Intake Grille 9359738008 Air Filter 9359739005 Filter Guide R 9359692003 Filter Guide L 9359693000 Front Panel 9359734000 Indicator PCB Assy 9705891043...
Page 20
INDOOR UNIT Drain pan Flap Description Part number Ref. 2 Panel Left Sub Assy 9360427014 3 Kit (Panel Right Assy) 9371361017 21 Evaporator Assy 9372585078 22 Distributor Assy 9371325378 23 Coupling Pipe Assy 9373038405 24 Kit (Panel pipe-L) Sub Assy 9371362014 25 Kit (Panel pipe-R) Sub Assy 9371363011...
Page 21
INDOOR UNIT Louver Base Sub Assy Ref. Description Part number Louver Base Sub Assy 9360432025 Louver 9359719007 Rod (Motor) 9359723004 Louver Link 9359726005 Louver Base 9359718000 Louver Spring 9359720003 Louver Stopper 9359724001 Louver Rod 9359725008 Step Motor H 9900297015 Louver Insulation R 9359721000 Louver Insulation L 9359722007...
Page 22
INDOOR UNIT Fan motor Ref. Description Part number Motor Mount 9377999016 Fan Motor Assy 9602389018 Motor Band A assy 9374647019 Motor Band B 9374648023 Reinforcement Motor Band 9378000018 Rubber 9385102002 Casing 9359704003 Kit (Cover Casing) Sub Assy 9371367019 Sirocco Fan Assy 9359701002 Joint Assy 9378038011...
Page 23
Ref. Description Part number INDOOR UNIT Control Box Assy 9377912015 Control unit Control Box A 9359712008 Control Box B 9359713005 Controller PCB Assy (30LBT) 9707393279 Controller PCB Assy (36LBT) 9707393286 Power Supply PCB Assy 9707398076 Terminal 3P 9703345012 Terminal 3P 9306489045 Reactor Assy 9707457018...
OUTDOOR UNIT Ref. Description Part number Top Panel Sub Assy 9374417032 Front Panel 9374094066 Fan Guard 9374330010 Grip Side 9374173013 Service Panel Sub Assy 9374415052 Right Panel Sub Assy 9374416127 Emblem Rear 9351355005 Valve Cover 9374174010 www.enindel.com 2008.01.18...
Page 25
OUTDOOR UNIT Ref. Description Part number Base Assy 9374166138 Condenser A Assy 9374433056 Separate Wall 9374413188 Fan Motor 9602717019 Propeller Fan Assy 9366378020 www.enindel.com 2008.01.18...
STA NDA RD AC C ES SO R I E S INDOOR UNIT Name and Shape Q'ty Application Part number Drain hose Adhesive type 70 x 230 9360464002 insulation VT wire For fixing the drain hose 313806350303 L 280 mm Coupler heat insulator For indoor side pipe joint (large)