S 2xx, S 3xx & S 4xx Canister Vacuums
5.18.2
S 27x
1. Remove the cap assembly (Section 5.6).
2. Remove the two Phillips screws securing the motor to the rear casing and
disconnect its electrical connections.
3. The location of individual components is shown in Figure 5-34.
Important:
When re-installing the motor care must be taken to ensure that the rubber
cushion (Figure 5-34, Item 4) and the motor seal (Figure 5-34, Item 7) are
correctly located! The speed control will vary depending on the type of power
selector switch installed.
Figure 5-34: S 27x Motor Assembly
1 Motor brushes
2 Clamping
bracket
3 Retaining screw
4 Rubber cushion
5 Retaining screw
6 Holding bracket
7 Motor seal
8 Motor
9 Retaining screw
10 Holding bracket
11 Retaining screw
12 Thermostat
13 Resistor
49
Technical Information
14 Speed control electronic:
EDL 202, S 271i - S 276i
EDL 302, S 280i -S 282i
EDL 402, S 278i
15 Retaining screw
16 Plug
17 Plug housing
18 Retaining screw
19 Retaining screw
20 Interference suppression
capacitor