1. Specifications Wall mounted Type Inverter, Heat pump Model name ASEH07KLTA ASEH09KLTA ASEH12KLTA Power supply 230 V~ 50 Hz Power supply intake Outdoor unit Available voltage range 198—264 V Rated Btu/h 6,800 8,500 11,600 Cooling 0.9—2.8 0.9—3.0 0.9—3.7 Min.—Max. Btu/h 3,100—9,600 3,100—10,200 3,100—12,600...
Page 7
Wall mounted Type Inverter, Heat pump Model name ASEH07KLTA ASEH09KLTA ASEH12KLTA NOTES: • Specifications are based on the following conditions: – Cooling: Indoor temperature of 27°CDB/19°CWB, and outdoor temperature of 35°CDB/24°CWB. – Heating: Indoor temperature of 20°CDB/15°CWB, and outdoor temperature of 7°CDB/6°CWB. –...
2. Dimensions 2-1. Models: ASEH07KLTA, ASEH09KLTA, and ASEH12KLTA Unit: mm 230.6 230.6 Outline of indoor unit for pipe inlet Ø65 for pipe inlet Ø65 317.6 306.6 - 4 - 2-1. Models: ASEH07KLTA, ASEH09KLTA, and ASEH12KLTA 2. Dimensions...
Page 9
¢ Installation space requirement Provide sufficient installation space for product safety. Unit: mm Wall hook bracket 40 or more 30 or more 176 or more 203 or more Outline of the indoor unit 1,500 or more - 5 - 2-1. Models: ASEH07KLTA, ASEH09KLTA, and ASEH12KLTA 2.
2-2. Pipe exit length from the rear Design the system considering the length of the pipes or hose exiting from the rear of the indoor unit. NOTE: Detailed shapes of the indoor unit and the tip of each pipe or hose may vary depending on the model.
4. Capacity table Capacity tables show each of following values calculated based on the outdoor temperature and the indoor temperature, under given Airflow Rate (AFR): For cooling capacity: Total Capacity (TC), Sensible Heat Capacity (SHC), and Input Power (IP) For heating capacity: Total Capacity (TC) and Input Power (IP) 4-1.
5. Fan performance 5-1. Air velocity distributions ¢ Models: ASEH07KLTA and ASEH09KLTA Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left & Right Unit: m/s Side view Horizontal louver: Up...
Page 15
¢ Model: ASEH12KLTA Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Horizontal louver: Up Vertical louver: Center Unit: m/s Top view Horizontal louver: Up Vertical louver: Left & Right Unit: m/s Side view Horizontal louver: Up Vertical louver: Center Unit: m/s Side view Horizontal louver: Down...
7. Safety devices Model Type of Protection form protection ASEH07KLTA ASEH09KLTA ASEH12KLTA Circuit protection Current fuse (PCB*) 250 V, 3.15 A More than 80°C Activate Fan motor speed down Fan motor Thermistor protection protection 80°C or less Reset Fan motor speed recover *PCB: Printed Circuit Board - 17 - 7.
9. Function settings To adjust the functions of this product according to the installation environment, various types of function settings are available. NOTE: Incorrect settings can cause a product malfunction. 9-1. Function settings by using remote controller Some function settings can be changed on the remote controller. After confirming the setting proce- dure and the content of each function setting, select appropriate functions for your installation envi- ronment.
Page 25
STEP 2: Selecting the function number and setting value 1. Press the TEMP./SELECT ( ) buttons to select the function Function number number. To switch between the left and right digits, press the MODE button. 2. Press the FAN SPEED button to proceed the setting value. To re- turn the function number selection, press the FAN SPEED button again.
Page 26
¢ Contents of function setting Each function setting listed in this section is adjustable in accordance with the installation environ- ment. NOTE: Setting will not be changed if invalid numbers or setting values are selected. Function setting list Function no. Functions Filter sign 30/31...
Page 27
2) Room temperature control for indoor unit sensor Depending on the installed environment, correction of the room temperature sensor may be re- quired. Select the appropriate control setting according to the installed environment. The temperature of the room temperature sensor is corrected as follows: Corrected temp.
Page 28
5) Indoor unit fan control for energy saving for cooling Enables or disables the power-saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation. Function number Setting value Setting description Factory setting Disable Enable ♦...
9-2. Custom code setting for wireless remote controller To interconnect the air conditioner and the wireless remote controller, assignment of the custom code for the wireless remote controller is required. NOTE: Air conditioner cannot receive a signal if the air conditioner has not been set for the custom code.
11. Optional parts 11-1. Others Exterior Part name Model name Summary Air Cleaning Air Cleaning Filter can be mounted to UTR-FA16-5 Filter the indoor unit. Remotely manage an air conditioning system using mobile devices such as smartphones and tablets. UTY-TFSXF2 Appropriate application for each region WLAN Adapter is required to use this option.
1. Specifications Type Inverter, Heat pump Model name AOEH07KLTA AOEH09KLTA AOEH12KLTA Power supply 230 V~ 50 Hz Power supply intake Outdoor unit Available voltage range 198—264 V Starting current Cooling 1,650 1,700 Airflow rate Heating 1,450 1,470 Type × Qty Propeller fan ×...
Page 35
OUTDOOR UNIT AOEH07–12KLTA OUTDOOR UNIT AOEH07–12KLTA...
2. Dimensions 2-1. Models: AOEH07KLTA, AOEH09KLTA, and AOEH12KLTA Unit: mm 4-M10 hole Pitch of bolts for installation Top view Side view Front view Side view Airflow Drain port Ø42 Bottom view Side view (Valve part) - 32 - 2-1. Models: AOEH07KLTA, AOEH09KLTA, and AOEH12KLTA 2.
3. Installation space 3-1. Models: AOEH07KLTA, AOEH09KLTA, and AOEH12KLTA ¢ Space requirement Provide sufficient installation space for product safety. CAUTION Keep the space shown in the installation examples. If the installation is not performed accordingly, it could cause a short circuit and result in a lack of operating performance.
Page 38
Multiple outdoor unit installation • Provide at least 250 mm of space between the outdoor units if multiple units are installed. • When routing the piping from the side of an outdoor unit, provide space for piping. • No more than 3 units must be installed side by side. When 4 units or more are arranged in a line, provide the space as shown in the following ex- ample “When an obstruction in the upper space:”.
Page 39
Outdoor units installation in multi-row Unit: mm Single parallel unit arrangement Multiple parallel unit arrangement 100 or more 200 or more 1,000 or more 2,000 or more 200 or more 400 or more 500 or more 1,000 or more 200 or more 250 or more 1,000 or more...
6. Capacity compensation rate for pipe length and height difference Height difference H Indoor unit is higher than outdoor unit Indoor unit is lower than outdoor unit Outdoor unit Indoor unit Outdoor unit Indoor unit Connection pipe Connection pipe 6-1. Models: AOEH07KLTA and AOEH09KLTA NOTE: Values mentioned in the table are calculated based on the maximum capacity.
6-2. Model: AOEH12KLTA NOTE: Values mentioned in the table are calculated based on the maximum capacity. Pipe length (m) COOLING — — — 0.858 0.868 — — 0.929 0.872 0.882 Indoor unit is higher than outdoor unit *1 — 0.960 0.933 0.876 0.885...
10. Electrical characteristics Model name AOEH07KLTA AOEH09KLTA AOEH12KLTA Voltage Power supply Frequency Max operating current* Starting current Circuit breaker current Power cable Wiring Cross-sectional spec.* Connection area cable* Limited wiring length NOTES: • *1: Maximum operating current is the total current of the indoor unit and the outdoor unit. •...
11. Safety devices Model Type of Protection form protection AOEH07KLTA AOEH09KLTA AOEH12KLTA Circuit Current fuse (PCB*) 250 V, 20 A protection 85—122°C Activate Fan motor stop Fan motor Thermal protection program protection 77—114°C Reset Fan motor restart 110 °C Activate Compressor stop Terminal protection program (Discharge temp.)
12. Accessories 12-1. Models: AOEH07KLTA, AOEH09KLTA, and AOEH12KLTA Part name Exterior Part name Exterior Drain pipe - 46 - 12-1. Models: AOEH07KLTA, AOEH09KLTA, and AOEH12KLTA 12. Accessories...