TECHNICAL DATA 12KHS32 FILE NO. SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Product Code No. Outdoor Model No. Product Code No. KHS1232 1 852 658 14 CH1232 1 852 754 05 Indoor Unit Outdoor Unit CH1232 KHS1232 701219 REFERENCE NO.
Page 2
IMPORTANT! When Transporting Please Read Before Starting Be careful when picking up and moving the indoor and out- door units. Get a partner to help, and bend your knees when This air conditioning system meets strict safety and operating lifting to reduce strain on your back. Sharp edges or thin alu- standards.
1. OPERATING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95°F DB / 71°F WB 115°F DB Cooling Minimum 67°F DB / 57°F WB 67°F DB Maximum 80°F DB / 67°F WB 75°F DB / 65°F WB Heating Minimum —...
3. DIMENSIONAL DATA Indoor unit KHS1232 14-3/16 38-31/32 7-13/16 Rear panel (Center point of gravity) Wireless remote control unit 1-61/64 2-13/64 19/32 Drain hose O.D. 1-1/4 5-19/32 Center of Narrow tube O.D. 1/4 tubing hole (For right rear) Wide tube O.D. 1/2...
Page 9
Outdoor unit CH1232 4 × 15/32 dia. hole Air intake intake Check port Air discharge 1/4" narrow tubing 23-15/16 2-3/8 service valve 1/2" wide tubing 29-17/32 2-1/4 11-1/32 service valve Dimension: in.
5. HEATING CAPACITY Indoor unit KHS1232 Outdoor unit CH1232 Outdoor temperature (°F DB) NOTE … Point of rating condition Black dot in the chart indicates the following rating condition. Indoor : 70°F DB Outdoor : 47°F DB / 43°F WB 2) Above characteristics indicate instantaneous operation, which does not take into consideration defrost operation.
6. AIR THROW DISTANCE CHART Indoor unit KHS1232 Cooling 230V Room air temperature : 80°F Fan speed : High Horizontal distance (ft.) 0° 30° 208V Room air temperature : 80°F Fan speed : High Horizontal distance (ft.) 0° 30°...
Page 14
Indoor unit KHS1232 Heating 230V Room air temperature : 70°F Fan speed : High Horizontal distance (ft.) 45° 60° 208V Room air temperature : 70°F Fan speed : High Horizontal distance (ft.) 45° 60°...
8. INSTALLATION INSTRUCTIONS 8-1. Installation Site Selection Indoor Unit To prevent abnormal heat WARNING generation and the possibility Indoor unit of fire, do not place obsta- cles, enclosures and grilles in front of or surrounding the air conditioner in a way that may block air flow.
Page 17
Outdoor Unit For stable operation of the air con- CAUTION ditioner, do not install wall-mount- AVOID: ed type indoor units under 4.9 ft. heat sources, exhaust fans, etc. (Fig. 4a) from the floor level. damp, humid or uneven locations. Indoor unit Wall choose a place as cool as possible.
Page 18
8-2. Remote Control Unit Installation Position Remote control unit The remote control unit can be operated from either a non-fixed position or a wall-mounted fixed position. Rear plate To ensure that the air conditioner operates correctly, do not install the remote control unit in the following places: Remote control unit mounting cradle in direct sunlight...
Page 19
Indoor Unit 2) Switch Positions for Up to 4 Units Table 2 shows the positions you can use for up to 4 indoor units installed in the same room. Table 2 Remote control unit Indoor unit Unit No. NOTE Address switch An indoor unit cannot be remote controlled if its remote (for receiving) control unit is too far away (more than 25 ft.).
Page 20
8-4. Recommended Wire Length and Size Regulations on wiring diameter differ from locality to locality. For field wiring requirements, please refer to NOTE your local electrical codes. Carefully observe these reg- Refer to the WIRING SYSTEM DIAGRAM for the ulations when carrying out the installation. meaning of “A”, “B”...
9. ELECTRICAL DATA G Electrical Characteristics Indoor unit KHS1232 Outdoor unit CH1232 Cooling Indoor Unit Outdoor Unit Complete Unit Rating Condition Fan Motor Fan Motor Compressor (a+b+c) 0.18 0.42 230V Performance 1,083 1,210 at 60 Hz 0.17 0.39 5.34 Single phase...
10. ELECTRIC WIRING DIAGRAMS Indoor unit KHS1232 WARNING To avoid electrical shock hazard, be sure to disconnect power before checking, servicing and/or cleaning any electrical parts. Terminal plate Thermistor Transformer Noise filter SG-OUT CONTROLLER Heater relay H. Thermo H M L LL...
Page 23
Outdoor unit CH1232 WARNING To avoid electrical shock hazard, be sure to disconnect power before checking, servicing and/or cleaning any electrical parts. Solenoid Connector coil Power transformer Noise filter Terminal plate Thermistor (coil) SEC TH1 Thermistor (air temp) SG-IN Thermistor (discharge) CONTROLLER Capacitor Power...
Page 24
For Parts or Service Contact SANYO FISHER SERVICE CORPORATION 1200 West Artesia Blvd., Compton, California, 90220, USA Oct. / ’95 / 1350 Printed in the U.S.A. 50 Beth Nealson Drive, Toronto, Ontario, M4H 1M6, CANADA...