2. Standard voltage (convertible) 3 AC 208 Frequency Rated load 15,3 Fuse rating 3 x 50 Connection cable, min. cross-section 4 x AWG 6 4 x 10 mm² (Connection cable not included) Technical datasheet: PW 6207 EL (electric) Date: 03.2015 Page: 11...
Page 12
Length of inlet hose 59 1/16“ 1500 mm Hourly water demand (average for 60° cotton program) Approx.19 Approx. 72 l/h determined at cold, hot and hard water connection gal/h Technical datasheet: PW 6207 EL (electric) Date: 03.2015 Page: 12...
Page 13
Drain connection on site (int. diameter) 2 15/16“ 75 mm [DN 70] Max. transient throughput 52.8 gal/min 200 l/min Vented drainage required. If ventilation is insufficient, fit Miele kit, Mat. No. 05238090. Drain manifolds serving several machines must be of sufficient cross-section. Fittings Without base...
2. Tension (commutable) 3 AC 208 Puissance de raccordement Fréquence 15,3 Fusible 3 x 50 Câble d’alimentation, section minimum 4 x AWG 6 4 x 10 mm² (Câble d’alimentation non fourni) Plan d’installation : PW 6207 EL (électrique) Date: 03.2015 Page: 14...
Page 15
(Couleurs 60°C) déterminée pour les raccordements gal/h eau froide, eau froide et eau dure S'il n'y a pas d'alimentation en eau chaude disponible, rac- corder à l’eau froide ! Plan d’installation : PW 6207 EL (électrique) Date: 03.2015 Page: 15...
Page 16
½ x 2 3/8 po 12 x 60 mm L’installation et le montage de l’appareil et du socle doivent être effectués en conformité avec les notices de montage fournies. Plan d’installation : PW 6207 EL (électrique) Date: 03.2015 Page: 16...
Page 17
L’installation doit exclusivement être effectuée par des installateurs agréés, conformément aux prescriptions et aux règle- ments applicables et aux règlements de prévention des accidents. Veuillez impérativement vous conformer à la notice de montage lors de l’installation de l’appareil. Sous réserve de modifica- tions! Plan d’installation : PW 6207 EL (électrique) Date: 03.2015 Page: 17...