Installation Instructions Gas cooktop KM 360 ® ® To prevent accidents and machine damage, read these instructions before installation or use. M.-Nr. 06 390 460...
Page 2
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
However, under certain circumstances it may be possible for installation in these applications. Please contact the Miele Technical Service Department with specific requirements. recommended not recommended not allowed...
The overhead cabinet depth, c, if unprotected, must not exceed 13" (330 mm). The minimum distance of combustible surfaces located above and to the sides of the cooktop, d, is 18" (457 mm). If the cabinet manufacturer recommends a greater distance, follow that manufacturers recommendation.
^ Rember to maintain the minimum safety distances to combustible surfaces: " (70 mm) between the cooktop and the back wall and - 12" (305 mm) between the cooktop and a side wall or tall unit to the right or left of the cooktop.
^ Guide the power cord through the cut-out. ^ Set the cooktop in the cut-out and center it. Securing the cooktop ^ Secure the cooktop in position with the supplied fixing brackets, a.
Power supply The automatic ignition requires that the cooktop be connected to a 120 VAC, 60 Hz power supply. The supply line should be protected by a 15 A breaker. Actual power consumption (during ignition only) is 25 W.
Installation and service must be performed by a qualified installer, service agency or the gas supplier. In Massachusetts a licensed plumber/gas fitter is required. This appliance must be installed with its own shut off valve and the included gas pressure regulator. Both the valve and the regulator must be easily accessible to the consumer to turn on or shut off the...
½" NPT c Regulator As shown in the above diagram, the included regulator must be used when connecting the Miele cooktop to your gas supply. This item has been customized by Miele to meet all applicable safety requirements. Make...
Page 11
Nominal Rating Table Auxiliary burner Max. output Min. output Normal burner Max. output Min. output Fast burner Max. output Min. output All burners Max. output NG (Natural gas) LP (Liquid propane gas) BTU/hr 3400 6000 1200 10200 1700 25600 Gas connection 0.26 1.76 0.35...
If the appliance is to be connected to a type of gas other than it was originally configured for, both the regulator and burners must be converted. A conversion kit is available as an optional accessory from the Miele Technical Service Department.
Page 16
Alterations rights reserved / 3606 M.-Nr. 06 390 460 / 06 en - USA...