2 screws 4 x 40 mm,
2 plugs 6 x 36 mm for securing the
cooker hood to the wall (only when
fitting into a 900 mm wide cabinet).
4 screws 4 x 25 mm for securing a
900 mm wide cooker hood.
4 adhesive labels to conceal the fixing
holes which are not required.
1 x T 20 angled screwdriver

Connection for air extraction

If the cooker hood is used at the
same time as a heating appliance
that relies on oxygen from the same
room, there is a risk in certain
circumstances of toxic fumes
building up.
It is essential that the "Warning and
Safety" instructions are observed.
The cooker hood should be installed
according to local and national
building regulations. Seek approval
from the building inspector where
necessary.
Only use smooth pipes or flexible
exhaust ducting made from
approved non-flammable materials
for exhaust ducting.
Use rigid exhaust ducting for ... EXT/
EXTA model cooker hoods. The
external motor can cause an
underpressure which can result in
the exhaust ducting distorting.
To achieve the most efficient air
throughput with the lowest noise levels,
please note the following:
- The diameter of the exhaust ducting
must not be smaller than the cross-
section of the exhaust duct (see
"Appliance dimensions"). This applies
in particular when using flat ducting.
- The exhaust ducting should be as
short and straight as possible.
- Only use wide radius bends.
- The exhaust ducting must not be
kinked or compressed.